Skip to main content
Springer logoLink to Springer
. 2026 Aug 31;20(1):922. doi: 10.1007/s11701-026-03854-z

Robotic-assisted total knee arthroplasty: accuracy, clinical outcomes, complications, learning curve and cost-effectiveness: a critical clinical review

Jakub Szymczak 1,✉, Marcin Łapiński 2, Artur Stolarczyk 2, Krzysztof Balawender 3
PMCID: PMC13529615  PMID: 42671659

Abstract

Robotic-assisted total knee arthroplasty (RA-TKA) has been adopted to improve surgical planning, bone preparation, component positioning, and limb alignment. This critical clinical review evaluates whether these technical gains improve outcomes that matter to patients and healthcare systems. The PubMed/MEDLINE, Web of Science, and Scopus databases were searched on July 6, 2026, using prespecified RA-TKA search terms and targeted searches for specific endpoints. A supplementary PubMed search on August 10, 2026, focused on soft-tissue balancing, ligament balancing, gap assessment, medial release, and alignment strategy. Evidence was prioritized from systematic reviews, meta-analyses, randomized trials, registry and database studies, health economic evaluations, and learning-curve studies. The most consistent finding is improved radiographic or technical accuracy, including fewer alignment outliers and closer execution of planned implant position. Evidence for patient-reported outcomes, pain, satisfaction, range of motion, and early recovery is more heterogeneous, and reported advantages are often modest or short-term. Safety appears acceptable in trained teams, although pin-related, registration, workflow, and conversion risks require explicit attention. Long-term survivorship superiority and broad cost-effectiveness remain insufficiently proven. RA-TKA improves precision more reliably than it improves durable patient-level outcomes. Its clinical value depends on patient selection, platform, alignment and balancing strategy, surgeon and team experience, volume, and cost structure.

Keywords: Robotic-assisted total knee arthroplasty, Total knee arthroplasty, Clinical outcomes, Alignment, Complications, Cost-effectiveness

Introduction

Total knee arthroplasty (TKA) is a mature reconstructive procedure with durable implant survival in registry and long-term series, yet survivorship does not fully describe the patient experience. Long-term registry synthesis indicates that many knee replacements remain in situ beyond 15 years, and contemporary reviews continue to report persistent pain, dissatisfaction, and variable function in a clinically relevant minority of patients [1–3]. For surgeons and health systems, evaluation extends beyond implant retention to predictable restoration of painless function with acceptable resource use and low revision risk.

Interest in RA-TKA arose from the observation that conventional instrumentation can produce variability in bone cuts, component position, alignment, gap balance, and soft-tissue handling. Robotic platforms attempt to reduce that variability through preoperative or intraoperative planning, registration, controlled bone preparation, haptic or navigation feedback, and quantitative assessment of alignment or soft-tissue balance. Recent systematic reviews and meta-analyses consistently support improved precision, but their conclusions are less uniform for pain, function, satisfaction, complications, revision, and cost-effectiveness [4–10]. This distinction matters because radiographic accuracy is an intermediate endpoint. It can plausibly influence outcomes, yet it cannot be treated as proof of clinical benefit without direct evidence.

A critical review is warranted because the evidence base is expanding faster than long-term clinical follow-up. Randomized trials, observational studies, registry analyses, and economic models address different questions and carry different biases. Some studies report improved alignment, some suggest early pain or recovery advantages, and others report comparable patient-reported outcome measures (PROMs) or no early revision advantage [11–17]. This critical clinical review evaluates whether robotic-assisted total knee arthroplasty improves outcomes that matter to patients and healthcare systems, with focus on accuracy, clinical outcomes, complications, learning curve, survivorship, and cost-effectiveness.

The review also addresses the practical problem of decision thresholds. A technology can be clinically attractive when it improves a process, yet adoption should depend on whether the improved process changes decisions, outcomes, or costs. For RA-TKA, the decision threshold differs for the individual surgeon, the hospital, and the patient. A surgeon may value reproducible execution and quantitative feedback; a hospital may require shorter LOS, fewer complications, or higher throughput; a patient may care about pain relief, confidence, and a knee that feels natural. The same evidence can therefore support adoption in one setting and restraint in another. This variability is a central part of clinical interpretation and prevents a single adoption threshold from fitting every setting.

Methods

Review design

This article was prepared as a critical clinical review. Systematic-review and meta-analytic methods were outside its design. The purpose was to synthesize clinically relevant evidence for orthopaedic surgeons, robotic arthroplasty teams, and clinical researchers. The review used documented searches of PubMed, Web of Science, and Scopus together with endpoint-based synthesis. Duplicate screening, formal risk-of-bias assessment, PRISMA-compliant reporting, and statistical pooling were outside the review design. Conclusions are framed as clinical interpretation of the available evidence.

Data sources and search strategy

The primary database searches were performed on July 6, 2026. Searches combined terms for robotic-assisted total knee arthroplasty, robot-assisted TKA, robotic total knee replacement, conventional or manual TKA, accuracy, alignment, component positioning, outliers, PROMs, pain, function, complications, revision, survivorship, learning curve, operative time, length of stay, and cost-effectiveness. Targeted searches addressed accuracy, PROMs, complications, survivorship, learning curve, cost-effectiveness, randomized trials, systematic reviews, registry studies, system-specific comparisons, and contextual TKA pain and survivorship literature. A supplementary PubMed search was performed on August 10, 2026, for soft-tissue balancing, ligament balancing, gap assessment, gap tensioning, medial release, varus TKA, functional alignment, kinematic alignment, load sensors, and reporting of alignment and balancing targets.

Eligibility and prioritization of evidence

Evidence was prioritized in the following order: recent systematic reviews and meta-analyses, randomized controlled trials, prospective comparative studies, registry and large database studies, health economic evaluations, and learning-curve analyses. Small case series, purely technical reports, cadaveric-only studies, unicompartmental knee arthroplasty studies, total hip arthroplasty studies, conference abstracts, and articles without clinical endpoint relevance were excluded or deprioritized unless they clarified a specific methodological issue.

Evidence synthesis

Retrieved evidence was organized into endpoint domains: accuracy and alignment, patient-reported outcomes, perioperative recovery, complications and safety, survivorship and revision, learning curve, cost-effectiveness, and patient selection. The synthesis distinguishes technical endpoints from patient-level outcomes. When evidence was heterogeneous, the manuscript states the disagreement directly. Claims about clinical superiority are restricted to endpoints for which direct comparative evidence exists.

Limitations of the review method

The synthesis therefore uses conservative language. When a study reported better radiographs and similar PROMs, the interpretation is technical benefit with uncertain patient-level translation. When a registry study reported fewer early readmissions or complications, the interpretation is an association that may be influenced by selection and institutional factors. When an economic model found cost-effectiveness, the interpretation is conditional on the model assumptions. These rules were applied consistently to reduce the risk that surrogate endpoints, observational associations, or modeled scenarios would be presented as proven clinical superiority.

Robotic-assisted TKA systems and mechanisms of action

Image-based and imageless platforms

RA-TKA encompasses several intervention types. Image-based systems typically use preoperative computed tomography or other imaging to support three-dimensional planning and implant sizing. Imageless systems rely on intraoperative mapping of bony landmarks, kinematic data, or registration workflows. The distinction affects radiation exposure, preoperative cost, operating-room workflow, registration error modes, and the type of planning information available to the surgeon. Comparative reviews and system-specific analyses show that platform-level differences make pooled conclusions difficult to translate to a specific operating room [18–21].

Active, semi-active, passive, and handheld systems

Robotic systems also differ in the level of machine assistance. Active systems perform a planned action under surgeon supervision; semi-active systems constrain or guide execution within a planned volume; passive navigation systems display information without physically constraining instruments; handheld systems add tracking and guidance to surgeon-held tools. These mechanisms may influence resection accuracy, soft-tissue protection, operative time, setup burden, tactile feedback, and conversion strategy. For clinical interpretation, a study of one platform should not be generalized to all platforms without checking whether the same imaging requirement, guidance mechanism, balancing workflow, and surgeon interface were used [19–23].

Planning, registration, bone preparation, and balance

The clinical pathway begins with planning, proceeds through registration, and ends with execution of resections and trial balancing. Planned-to-achieved resection accuracy and soft-tissue balance are separate dimensions. Accurate bone preparation does not determine the final gap pattern because deformity, osteophytes, contracture, ligament behavior, component choices, and the alignment target also influence the soft-tissue state. Robotic and sensor-based tools can quantify gaps or tension and can support controlled component adjustment. The surgeon still selects the target and decides whether measured findings warrant component repositioning, recut, insert change, or selective release, followed by reassessment [26, 94–96]. Randomized and prospective studies show that component position, alignment, measured balance, and patient outcomes can change independently [24–27]. Section 4.3 addresses this distinction in detail.

Why heterogeneity matters

System heterogeneity affects evidence interpretation in four ways. First, accuracy can be measured as implant position, limb alignment, bone-resection error, gap symmetry, or deviation from a plan. Second, clinical endpoints may depend more on rehabilitation, pain protocols, patient selection, and baseline expectations than on millimetric changes in resection. Third, costs differ by capital purchase, maintenance, disposable instruments, imaging, and case volume. Fourth, the learning curve is distributed across surgeons, assistants, scrub teams, radiology, scheduling, sterilization, and implant logistics. The evidence base is therefore platform- and context-sensitive.

The same heterogeneity affects consent and shared decision-making. Patients may hear the word robotic and assume automation, smaller incisions, lower complication risk, or guaranteed precision. The surgeon performs the operation, selects and may modify alignment targets, interprets gap or tension measurements, balances the knee, and manages complications. Robotic assistance can make execution and measurement more repeatable. Acceptance thresholds and the response to measured soft-tissue findings remain clinical decisions, and final outcomes also depend on diagnosis, anatomy, implant choice, fixation, rehabilitation, comorbidities, and expectations.

The studies cited in Table 1 are also discussed above because the clinical relevance of any table entry depends on whether the same system design was used in the source study.

Table 1.

Robotic-assisted TKA systems and technical characteristics

System category Imaging requirement Assistance mechanism Potential value Limitations Citations
CT-based robotic arm Preoperative CT Plan-linked robotic or haptic execution Three-dimensional planning and controlled cuts Radiation, imaging cost, registration and workflow burden [18, 19]
Imageless platform Intraoperative mapping Navigation or robotic guidance after landmark registration Avoids preoperative CT and may simplify access Relies on accurate registration and consistent landmark capture [22, 23]
Handheld robotics Platform dependent Tracked handheld cutting or burring instruments Potentially lower footprint and flexible workflow Evidence remains platform-specific and early for some devices [28, 29]
Gap-tensioning or balancing systems Platform dependent Quantitative laxity and balance feedback Quantitative gap/laxity data for target selection and reassessment Measured gaps require a defined target and surgeon interpretation [26, 94, 96]

Accuracy, implant positioning, and alignment

Component positioning

The most reproducible advantage of RA-TKA is technical precision. Meta-analyses and randomized trials report improved planned-to-achieved accuracy, more consistent component positioning, and fewer radiographic outliers compared with conventional instrumentation [23–25, 28, 30–33]. These findings are clinically plausible because inaccurate femoral or tibial component position can affect load distribution, stability, patellofemoral tracking, wear, and later failure. The degree to which a reduction in outliers changes an individual patient’s pain or function remains less certain.

Coronal and sagittal alignment

Coronal-plane alignment has been the dominant endpoint in early RA-TKA studies; sagittal alignment, posterior tibial slope, joint-line position, and femoral flexion are also relevant. Several comparative trials found better radiographic alignment or fewer outliers with robotic assistance and similar short-term function [24–25, 31–33]. This pattern supports a technical effect and leaves the patient-level effect unresolved. Functional and kinematic strategies change the target itself and carry assumptions about the intended gap pattern and soft-tissue envelope; these variables require separate assessment from resection accuracy (Sect. 4.3).

Rotational alignment and soft-tissue balance

Rotational alignment and soft-tissue balance require separate interpretation from coronal component accuracy because the soft-tissue state is patient specific. Two knees with equally accurate resections can show different medial and lateral gaps because deformity, osteophytes, contracture, ligament properties, posterior capsular tension, and the selected alignment target differ. Balance is multidimensional: extension, mid-flexion, and flexion laxity, anteroposterior stability, and the intended rectangular or physiological asymmetric gap pattern may each affect intraoperative decisions. Quantitative measurement can improve repeatability of gap assessment, yet repeatability does not establish the clinically preferred target for a given knee. In 517 consecutive RA-TKAs, Orsi et al. found poor agreement between manual and robotic mediolateral balance assessment (ICC 0.368), with surgeon-specific ICCs from 0.152 to 0.633 [94]. These findings document disagreement between subjective and robotic measurements; they do not identify a universal optimal value or prove that one assessment method yields better patient outcomes.

Conventional TKA can also use a structured sequence of assessment, selective intervention, and reassessment. In a retrospective single-surgeon series of 60 primary TKAs for varus deformity greater than 10°, Gurbuz et al. applied a stepwise medial release protocol with gap-balancer reassessment at 0° and 90°; by the study’s own definition, 85% of knees reached optimal medial balance at 0° and 80% at 90° after completion of the sequence [97]. These cohort results illustrate a systematic conventional comparator and should not be treated as a validated universal release algorithm. Sequential release can alter several stability dimensions at once. In six cadaveric cruciate-retaining TKAs, Sakai et al. found that progression from deep medial collateral ligament release to posteromedial capsule and superficial MCL release increased the medial gap by 3.2 mm in extension, 6.8 mm at 45°, and 7.2 mm at 90°; anterior translation at 90° increased by 11.5 mm from the first to the third stage [95]. The findings support reassessment across flexion angles after each intervention and caution against pursuing gap symmetry through excessive release.

Robotic and sensor-based systems add quantitative gap information and controlled execution to this same clinical sequence: define the alignment and balance target, measure the soft-tissue state, choose a response, and remeasure after component adjustment, bone recut, insert selection, or selective release. The target and response remain surgeon decisions. In the randomized trial by Lizcano et al., robotic gap-tensioning did not improve 6-month Timed Up and Go or Stair Climb Test results [26]. RASKAL found no KOOS-12 difference for robotic versus computer-assisted surgery and no KOOS-12 difference for functional versus mechanical alignment through two years; soft-tissue release was more frequent with mechanical alignment than functional alignment (44.8% vs. 8.1%), showing that alignment philosophy can strongly influence release requirements independently of the robotic comparison [35]. Functional alignment itself includes multiple routes to different component positions and flexion-gap configurations [99]. Indirect evidence from a multicentre sensor RCT showed fewer quantitatively unbalanced knees with sensor guidance (9.4% vs. 36.8%) without a corresponding two-year KOOS4 difference [96]. Quantitative gap data therefore require explicit target definitions and clinical interpretation.

Alignment outliers

Reduction in outliers is the accuracy endpoint with the clearest face validity. Systematic reviews and randomized trials repeatedly report fewer knees outside planned alignment thresholds after RA-TKA [6–7, 9, 11, 30]. However, the definition of an outlier varies by study. Some use hip-knee-ankle angle, some use component coronal or sagittal position, and newer studies may use phenotype-based or functional alignment targets. A review can therefore support improved precision while still rejecting a universal claim of clinical superiority.

Accuracy as an intermediate endpoint

Accuracy is a prerequisite for delivering a planned reconstruction. Patient priorities concern pain, function, recovery, complications, durability, and cost. A technically precise reconstruction has limited clinical value when those outcomes do not improve. Contemporary meta-analyses show more consistent radiographic benefit than PROM benefit [4, 9–10, 12]. This separation should be explicit in consent discussions, procurement decisions, and research design. This conceptual pathway linking robotic planning, execution accuracy, alignment, clinical outcomes, survivorship, and cost-effectiveness is summarized in Fig. 1. Table 2 summarizes the comparative evidence across the major clinical and health-system domains.

Fig. 1.

Fig. 1

Conceptual pathway from robotic planning to clinical outcomes. Robotic planning and registration may improve execution accuracy; execution accuracy may influence component position and alignment. Soft-tissue assessment and surgeon-directed intervention form a related, distinct step that can influence gap behavior and stability. These technical states may affect early recovery, PROMs, revision, survivorship, and cost-effectiveness. Evidence is strongest at the planning-to-accuracy step, mixed for early clinical outcomes, and limited for long-term survivorship and economic value

Table 2.

Evidence summary for RA-TKA versus conventional TKA

Endpoint domain Direction of evidence Consistency Clinical interpretation Limitations Citations
Accuracy and alignment Favors RA-TKA High for radiographic precision Fewer outliers and closer planned execution Targets and measurement methods differ [6, 7, 9]
PROMs and pain Mixed Low to moderate Some early or subgroup benefits; many comparisons are similar Short follow-up, MCID reporting, protocol confounding [14, 15, 17, 36]
Perioperative recovery Mixed Moderate Possible improvements in selected settings ERAS pathways and discharge rules confound attribution [37–39]
Complications Generally comparable Moderate Safe in trained teams; specific device-related issues exist Rare harms require large datasets [40–42]
Survivorship/revision Uncertain Low to moderate Long-term superiority is not established Follow-up duration and registry coding limitations [43–45]
Cost-effectiveness Context dependent Low to moderate Depends on price, volume, offsets, and durability of benefit Model assumptions and national reimbursement context [46–49]

Alignment precision may gain clinical relevance as targets become more individualized. Restricted kinematic, functional, and phenotype-based plans require reproducible delivery of a defined target, including its soft-tissue assumptions. Accurate execution addresses delivery of the selected plan. Target validity and the response to measured laxity require separate clinical evidence. Pooled comparisons of robotic and manual TKA are difficult to interpret when studies omit target boundaries, gap goals, balancing methods, or intervention rules [35,98–100]. Table 3 summarizes the accuracy and alignment findings across component positioning, coronal and sagittal parameters, functional or kinematic targets, and image-based versus imageless systems.

Table 3.

Accuracy and alignment outcomes

Endpoint Typical finding Clinical relevance Limitations Citations
Coronal alignment Reduced deviation and fewer outliers May improve load distribution if target is appropriate Clinical translation remains inconsistent [9, 30, 31]
Component positioning Closer planned-to-achieved position in many trials Supports reproducible execution Measurement protocols differ [24, 25, 28]
Sagittal alignment and slope Potentially more controlled tibial slope and component flexion May affect kinematics and flexion stability Outcome linkage is incompletely proven [33, 50]
Functional or kinematic targets Growing evidence base May support individualized component and soft-tissue targets Gap target and release strategy must be specified; outcome benefit remains uncertain [27, 34, 35, 99, 100]
Image-based versus imageless accuracy Both can achieve accurate radiographic results in selected trials Platform choice can be individualized Few direct randomized comparisons [22, 23]

Clinical outcomes and patient-reported outcome measures

Pain outcomes

Clinical outcomes show less consistent separation than radiographic outcomes. Randomized and systematic-review evidence suggests that RA-TKA may reduce early knee-specific pain or support faster early recovery in some settings, but the magnitude and durability vary [15–17, 51]. Pain after TKA is multifactorial, including preoperative pain sensitization, mental health, expectations, inflammation, component position, soft-tissue balance, and rehabilitation. Robotic precision can address only part of that pathway.

Functional outcomes

Functional outcomes measured by Oxford Knee Score, Knee Society Score, WOMAC, Knee injury and Osteoarthritis Outcome Score, timed recovery measures, gait analysis, and wearable metrics are heterogeneous. Some trials report functional advantages, whereas others find similar outcomes despite better alignment [15–16, 26, 36, 51]. This pattern may reflect underpowered trials, early endpoints, variable rehabilitation, ceiling effects in modern TKA, and the possibility that alignment precision benefits selected subgroups. Studies that introduce a robotic platform together with a new alignment or balancing strategy require separate attribution of technology and strategy effects (Sect. 4.3) [35].

Range of motion

Range of motion (ROM) is attractive because it is easy to measure, but it is influenced by preoperative stiffness, surgical exposure, pain control, swelling, implant design, component rotation, posterior tibial slope, and rehabilitation adherence. Robotic workflows may improve control of slope and balancing variables, yet evidence for a consistent ROM advantage remains limited and should not be overstated [4–5, 11, 35]. Future trials should report baseline ROM, rehabilitation protocols, manipulation rates, and MCID-based interpretation.

Forgotten Joint Score, satisfaction, and perception of the knee

Satisfaction and joint awareness are clinically meaningful because a well-positioned implant can still feel artificial, painful, unstable, or disappointing. A systematic review focused on satisfaction found no consistent increase in satisfaction after robotic TKA, and RCT and subgroup analyses suggest that selected patients may report better knee-specific pain or functional recovery [14, 17, 36, 52]. Patient expectation management remains essential. Consent language should describe robotic assistance as a tool for more reproducible execution and should avoid guarantees of a forgotten joint.

Minimal clinically important difference

Statistical differences in PROMs can be difficult to interpret when the absolute difference is small or when baseline scores differ. MCID-based reporting helps separate measurable score changes from changes patients are likely to perceive. Registry and cohort analyses comparing MCID rates are useful because they ask whether more patients cross a clinically relevant threshold, but such studies remain vulnerable to confounding [8, 52–53]. Manuscripts should therefore report both mean differences and the proportion of patients achieving MCID or patient acceptable symptom state.

Short-term versus mid-term and long-term outcomes

Many clinical advantages reported for RA-TKA are early. Early pain, walking, discharge, or satisfaction differences can matter to patients and hospitals, but they do not prove durable superiority. Mid-term and long-term comparative evidence is still developing, and some meta-analyses conclude that clinical results are comparable despite better radiographic precision [9–10, 43, 54]. A balanced review should therefore separate early recovery signals from durable patient-level outcomes.

Clinical outcome reporting should also account for ceiling effects. Contemporary TKA already produces large average improvements in pain and function, leaving limited room for a technology to show additional average benefit in an unselected population. A small mean difference may be clinically relevant if it shifts a larger fraction of patients above a satisfaction threshold; it may have little clinical importance when both groups already exceed accepted outcome targets. An unchanged mean can also hide benefit in one subgroup and harm or no benefit in another. Future RA-TKA trials should therefore report responder analyses, distributional plots, baseline-adjusted estimates, and prespecified subgroups alongside mean score comparisons. Table 4 summarizes the reported patterns in patient-reported and functional outcomes, including pain, knee-specific scores, gait measures, and satisfaction.

Table 4.

Patient-reported and functional outcomes

Outcome measure Typical finding MCID issue Follow-up Interpretation Citations
Pain scores Some early benefit in selected trials Mean differences may not reach MCID Early to 1 year Potential early effect; durability uncertain [17, 51]
Oxford Knee Score / Knee Society Score Often similar or modestly improved Report mean scores and MCID rates Short to mid-term Clinical effect is heterogeneous [15, 36, 52]
WOMAC / KOOS Mixed across reviews Scale-specific thresholds needed Short to mid-term Interpret with baseline severity and protocols [4, 5, 8]
Gait and wearable metrics May detect recovery differences missed by PROMs MCID often less established Early to 1 year Useful research endpoint, not yet routine decision driver [16, 55]
Satisfaction / Forgotten Joint Score No consistent satisfaction advantage Patient acceptable symptom state may help Variable Expectation management remains central [14, 52]

Perioperative outcomes and early recovery

Operative time

Operative time is affected by registration, planning adjustments, pin placement, bone preparation, trialing, and team familiarity. Meta-analyses and learning-curve studies indicate that robotic procedures may take longer during adoption, with efficiency improving as teams gain experience [56–59]. Time effects should be evaluated at surgeon, team, and institutional levels.

Blood loss and transfusion

Potential mechanisms for reduced blood loss include avoidance of intramedullary femoral instrumentation, controlled resections, and less soft-tissue trauma. Some meta-analytic evidence evaluates blood loss across alignment or technology approaches that do not violate the femoral canal [38, 60–61]. The clinical importance of this endpoint may be lower in settings with modern blood management, tranexamic acid, and low transfusion rates.

Length of stay and discharge destination

Length of stay (LOS) and discharge destination are health-system endpoints. Database and economic studies report shorter stays or reduced post-acute care use in some robotic cohorts; ERAS pathways, patient selection, insurance structure, institutional discharge practices, and center volume may contribute to these findings [39, 62–64]. A credible analysis should adjust for baseline health, social support, anesthesia, outpatient pathways, and calendar year.

Early mobilization and rehabilitation

Early mobilization is clinically meaningful when it reduces pain, improves confidence, supports earlier discharge, or avoids institutional rehabilitation. Randomized trials and cohort studies report possible early recovery advantages with variable results [37, 50–51, 65]. Attribution is difficult because a center adopting robotics may also update education, prehabilitation, anesthesia, discharge criteria, and outpatient rehabilitation.

Opioid use

Opioid use is an important patient and public-health endpoint. Studies that report less early pain or faster recovery should also report opioid protocols, prescribing rules, refill data, and multimodal analgesia use. Attribution of opioid differences to robotics is uncertain when institutional analgesic protocols differ. Existing evidence supports cautious discussion and does not justify a general claim of reduced opioid exposure [4, 66].

Perioperative endpoints are useful for implementation decisions because they are measurable during early adoption. They should be collected prospectively as part of a local robotic TKA program: incision-to-closure time, total room time, setup time, tourniquet strategy, blood loss, LOS, discharge destination, same-day discharge success, readmission, and 90-day cost. Without local measurement, a hospital may adopt a platform expecting efficiency gains that depend on another institution’s case mix, staff model, and reimbursement structure.

Complications and safety

General complications

RA-TKA appears generally safe when performed by trained teams, and large database studies have not shown a broad signal of excess early complications compared with manual or navigated procedures [39, 42, 67–68]. However, safety evidence should be interpreted by complication type. Rare complications require large datasets, while technical adverse events require detailed operative reporting that is often absent from administrative data.

Robot-specific adverse events

Robot-specific safety concerns include pin-site fractures, pin-track infection, registration error, array loosening, line-of-sight loss, software or hardware interruption, workflow error, and conversion to conventional instrumentation. A systematic review of complications and downsides described these concerns, and more recent meta-analysis focused on pin-associated periprosthetic fractures [40–41]. Even if uncommon, these events should be reported separately from standard TKA complications.

Pin-related complications

Tracking pins create a risk pathway that is absent in conventional TKA. The absolute event rate appears low, but pin placement, bone quality, obesity, postoperative fall risk, and drill technique may influence risk. The presence of this device-specific harm reinforces the need for procedure-specific consent language and registry fields that capture pin-related complications [41].

Registration and workflow errors

Registration errors can convert a high-precision tool into a misleading guide. Verification steps, surgeon vigilance, and team training are safety measures. Workflow disruption may also lengthen anesthesia time or increase fatigue during adoption. Learning-curve and workload studies support deliberate team training, proctoring, and standardized setup [69–70].

Conversion to conventional technique

Conversion to conventional technique is a planned contingency in a safe implementation strategy. Conversion may be required for registration failure, hardware interruption, unexpected anatomy, tracker instability, or time pressure. Studies should report conversion frequency and reasons because conversion affects operative time, costs, and patient consent. Administrative databases rarely capture this endpoint with sufficient granularity.

Readmissions and reoperations

Readmissions and reoperations are attractive safety endpoints because they are clinically relevant and measurable in large datasets. Some national analyses report lower readmission or complication rates after robotic TKA, whereas other registry analyses show no early revision advantage [39, 45, 67, 71]. These differences may reflect patient selection, coding, institutional adoption patterns, and residual confounding.

Safety reporting should use the denominator of all attempted robotic cases, including converted cases. Excluding converted cases can make the robotic cohort appear safer than it was in practice. Investigators should also separate intraoperative technical events from postoperative medical complications and should report whether adverse events occurred during the learning phase. This level of detail is needed for hospitals deciding how to train teams and how to monitor early adoption. Table 5 summarizes the principal complication categories and RA-TKA-specific safety concerns.

Table 5.

Complications and safety concerns

Complication category RA-TKA-specific issue Comparative evidence Clinical interpretation Citations
General medical/surgical complications No robotic-specific mechanism for many events Large datasets generally reassuring Do not infer superiority without adjustment [42, 67, 68]
Pin-related events Fracture, infection, pain, tracker-site problems Rare but specific to tracked systems Consent and technique should address risk [41]
Registration/workflow error Incorrect mapping or tracker instability Usually underreported Requires standard checks and conversion plan [40, 69]
Readmission/reoperation May improve or remain similar depending on cohort Confounded observational signal Interpret by dataset and adjustment strategy [39, 45, 71]
Vascular injury Potential interaction with constrained cutting and exposure Large retrospective data suggest possible lower odds Rare-event findings need cautious replication [72]

Implant survivorship and revision risk

Why survivorship matters

Survivorship is the most important long-term health-system endpoint because revision surgery is costly, morbid, and often less predictable than primary TKA. Long-term conventional TKA survivorship is already high, so a new technology must produce either a meaningful absolute reduction in revision risk, a clear improvement in patient-level outcomes, or cost offsets sufficient to justify implementation [1, 46, 73].

Aseptic loosening, instability, malalignment, and mechanical failure

The mechanistic argument for improved survivorship is strongest when revision is caused by malalignment, instability, poor component position, or mechanical overload. RA-TKA may reduce some technical contributors to failure. Modern failure pathways also include infection, patient factors, fixation biology, polyethylene wear, instability unrelated to coronal alignment, and trauma. A reduction in outliers remains a hypothesis for improved survivorship; direct long-term evidence is required.

Registry and long-term comparative evidence

Current registry and database evidence does not establish consistent long-term survivorship superiority. A systematic review and meta-analysis focused on survivorship found the question still developing, and American Joint Replacement Registry analyses have reported no early revision advantage for robotic or navigated TKA in some comparisons [43–45]. More recent transition and failure-mode analyses are useful because they examine adoption at the surgeon or institutional level, but follow-up remains short for a procedure intended to last decades [74].

Why long-term superiority remains uncertain

Long-term superiority remains uncertain because RA-TKA adoption is recent, platforms have changed, early adopters may differ from later adopters, and alignment philosophy is evolving. Registry data can provide scale, but they may lack component-level planning information, robotic platform details, alignment targets, intraoperative balance data, and PROMs. The appropriate conclusion is restrained: RA-TKA improves technical precision, but direct evidence that it consistently reduces revision risk or improves implant survivorship is not yet sufficient.

Survivorship studies also need to separate causes of revision. A technology designed to improve alignment and execution would be expected to affect mechanically mediated failure more than infection, periprosthetic fracture after trauma, or patient factors unrelated to implant position. All-cause revision is clinically relevant, but it may dilute a mechanical effect. Conversely, focusing only on aseptic mechanical revision can miss other harms or costs. The most informative registries will link robotic platform, alignment target, component position, fixation, PROMs, and cause-specific revision.

Learning curve and implementation

Surgeon learning curve

The learning curve involves more than becoming familiar with a console. Surgeons must learn case setup, registration, planning adjustment, bone preparation, balancing interpretation, troubleshooting, and conversion criteria. Systematic reviews and platform-specific analyses show that operative time and workflow generally improve with experience, although the number of cases required varies by platform, surgeon background, and institutional support [57, 75–76].

Team learning curve

The operating-room team learning curve may be as important as the surgeon learning curve. Staff must manage arrays, pins, draping, calibration, instrument flow, implant logistics, sterilization, troubleshooting, and room turnover. Initial institutional experiences and workload studies show that efficiency and perceived workload can change as the team gains experience [70, 77–78].

Operative workflow

Workflow effects vary by setting. Some high-volume settings may recover efficiency after early adoption, and implant-agnostic or handheld systems may reduce footprint or setup burden. Studies from specialty hospitals, time-series analyses, and multicenter efficiency reports suggest that robotic TKA can approach conventional efficiency under favorable conditions [29, 58, 79]. These findings require local workflow analysis before application to low-volume centers.

Case volume and institutional experience

Case volume is central to implementation because fixed costs, team familiarity, and schedule predictability improve when the platform is used frequently. Registry and adoption analyses show rapid growth of RA-TKA in the United States and suggest that institutional volume is associated with operative efficiency [59, 80]. A low-volume setting may face the same capital and training burden while receiving fewer efficiency gains.

Training, credentialing, and standardization

Training should include platform-specific certification, supervised cases, conversion planning, complication reporting, data capture, and periodic review of alignment and PROM outcomes. Credentialing should avoid equating attendance at a training session with proficiency. Institutions should track setup time, operative time, conversion, complications, readmission, PROMs, discharge destination, and cost during adoption.

Implementation should also include a stop-and-review process. If early cases show prolonged operative time, registration problems, conversion, pin complications, or no measurable recovery benefit, the team should revise workflow before expanding indications. If efficiency improves and local outcomes support value, use can broaden in a data-informed manner. This staged approach is particularly important when acquisition is justified to administrators, surgeons, and patients on the basis of benefits that may be context dependent. Table 6 summarizes the main learning-curve and implementation barriers and the corresponding mitigation strategies.

Table 6.

Learning curve and implementation barriers

Domain Observed issue Impact Mitigation strategy Citations
Surgeon workflow Registration and planning add steps early Longer operative time during adoption Proctoring, checklist, case sequencing [57, 75]
Team workflow Array, pin, calibration, and implant logistics Room turnover and workload burden Dedicated team training and standard setup [70, 77]
Platform differences Learning curve varies by system Generalizability is limited Report platform-specific learning curves [29, 76]
Volume Low case volume dilutes learning and cost offsets Less efficient implementation Match acquisition to projected use [59, 80]
Data capture PROMs, balance data, and conversion often missing Weak local quality assurance Create a robotic TKA registry dashboard [35, 81]

Cost-effectiveness and health economics

Capital, maintenance, and disposable costs

The economic case for RA-TKA begins with capital purchase, service contracts, software, disposables, training, imaging, room time, and opportunity cost. Markov models and cost analyses show that conclusions are highly sensitive to assumptions about purchase price, case volume, revision reduction, LOS, post-acute care, and quality-of-life gains [46–48, 82]. Model results require reassessment before transfer between reimbursement systems.

Imaging-related costs and operating-room time

CT-based systems add imaging cost and radiation exposure; imageless systems may reduce that burden but can differ in registration workflow and planning information. Operating-room time can either add cost or become neutral after adoption, depending on local efficiency. Public health-system analyses, hospital cost studies, and platform-specific evaluations show that small changes in LOS, tray use, and operative time can shift the economic result [58, 63, 82–83].

Potential savings

Potential savings include shorter LOS, fewer discharges to inpatient rehabilitation, lower readmission cost, fewer complications, reduced revision, more predictable inventory, and improved tray efficiency. These offsets are plausible but should be measured locally. Database studies reporting reduced readmission or discharge burden must be interpreted alongside patient selection and institutional pathway differences [39, 63–64, 84].

Volume thresholds

Volume is the main modifiable economic variable after acquisition. High-volume arthroplasty centers can spread fixed costs across more cases, develop efficient teams, and collect enough data for quality assurance. Low-volume centers may face higher per-case cost and a slower learning curve. Analyses of adoption and institutional volume support evaluating projected annual use before purchase [59, 80, 85].

Cost-effectiveness uncertainty

Cost-effectiveness remains uncertain because the largest possible long-term offset is revision reduction, and that benefit has not yet been proven consistently. Economic evaluations should run scenarios with zero, modest, and optimistic revision benefit and should vary capital price, service cost, disposable cost, operative time, LOS, and utility gain [49, 73, 86–87]. Procurement decisions should be linked to measured local outcomes and independent economic assumptions.

A practical economic audit should be performed before and after adoption. Before adoption, the institution should estimate annual case volume, expected robotic utilization, implant contracts, imaging requirements, disposable costs, service costs, staffing needs, room time, and baseline revision and readmission rates. After adoption, the institution should compare observed outcomes with the assumptions used to justify purchase. If the economic case depends on lower revision at 10 years, the hospital should recognize that early financial performance will depend on shorter-term offsets such as LOS, post-acute care, tray management, and throughput. Table 7 summarizes the principal cost drivers, potential offsets, evidence status, and health-system dependencies relevant to RA-TKA.

Table 7.

Cost-effectiveness considerations

Cost driver Potential offset Evidence status Health-system dependency Citations
Capital and service contract High volume spreads fixed cost Highly model dependent Strong [46, 47]
Disposables and trays Tray reduction and workflow standardization Emerging evidence Moderate [82]
Imaging May be absent in imageless systems Platform dependent Moderate [21, 23]
Operating-room time Learning curve may improve efficiency Variable Strong [58, 59]
LOS and post-acute care Shorter stay or less rehabilitation use Confounded but clinically relevant Strong [39, 64]
Revision reduction Largest long-term offset if real Unproven as a consistent benefit Strong [43, 73]

Patient selection and clinical indications

Standard primary TKA

For routine primary TKA without major deformity, the marginal value of RA-TKA is uncertain. Accuracy may improve, but many patients already do well after conventional TKA, and short-term PROM differences are often small or inconsistent [9–10, 14]. Routine use may still be reasonable in a high-volume center if local data show improved efficiency, outcomes, or teaching value.

Severe deformity and complex anatomy

Patients with severe coronal deformity, extra-articular deformity, retained hardware, prior fracture, or distorted landmarks may plausibly benefit from planning, registration, and controlled execution. Systematic review evidence in moderate-to-severe deformity and complex primary or revision-like cases supports interest in selective use, although direct proof of superior long-term outcomes remains limited [88–90].

High functional expectations and quantitative balancing

High-demand patients may value faster recovery, lower joint awareness, and greater confidence, and their expectations may increase the clinical importance of residual symptoms. Quantitative gap data can support individualized component and soft-tissue decisions. Current evidence has not established a balance phenotype in which robotic use produces superior patient-reported outcomes. The robotic gap-tensioning RCT reported similar functional testing at 6 months [26], and RASKAL reported similar KOOS-12 through two years for the technology and alignment comparisons [35]. In a separate randomized trial in which both groups underwent RA-TKA, functional alignment required fewer soft-tissue releases than mechanical alignment (16% vs 65%; P < 0.001), whereas the primary two-year Forgotten Joint Score did not differ significantly (70.1 vs 64.4; P = 0.10) [91]. Functional alignment also covers several combinations of initial alignment, preserved component position, and flexion-gap target [99]. Studies of high-demand patients should define the target, balance method, and intervention rules before attributing any subgroup effect to robotic assistance.

Obesity and high-risk groups

Obesity and comorbidity can increase technical difficulty and complication risk. RA-TKA may assist execution in challenging anatomy. High-risk patients retain medical and biological risks that robotic precision cannot eliminate. Current evidence is insufficient to define obesity, age, sex, bone quality, or psychosocial risk as independent indications. Future studies should test effect modification across these groups.

Selective versus routine use

Selective use is a rational interim strategy where resource constraints are real and long-term superiority is unproven. Potentially higher-value scenarios include severe deformity, complex anatomy, cases in which quantitative balance assessment may aid difficult intraoperative decisions, high-volume programs with established workflows, and research environments capturing PROMs and registry outcomes. Routine use becomes more defensible when local volume, efficiency, outcome tracking, and cost structure support value.

Patient selection should be revisited as evidence matures. If future trials identify reproducible benefit in a deformity phenotype, ligament-balance phenotype, alignment phenotype, or recovery-risk phenotype, selection can become evidence-based. Current selection still depends on clinical judgment and local context. Surgeons should avoid presenting RA-TKA as universally superior and should explain why it may or may not add value for the specific knee being treated.

Practical clinical framework

The practical decision is whether RA-TKA adds value in a specific patient, surgeon, platform, and health-system context. The sources in Table 8 are discussed in the preceding sections and show why a selective framework is currently more defensible than a universal claim of benefit. A practical decision framework for selective RA-TKA use is presented in Fig. 2.

Table 8.

Clinical scenarios in which RA-TKA may or may not provide added value

Clinical scenario Potential value Supporting rationale Evidence certainty Practical limitation Citations
Standard primary TKA Modest Accuracy improves, PROM advantage is inconsistent Moderate for accuracy; low for superiority Added cost may exceed benefit [9, 10]
Severe varus/valgus deformity Potentially higher Planning and controlled execution may assist correction Low to moderate Few long-term comparative data [88, 90]
High-volume arthroplasty center Higher Efficiency, learning, and fixed-cost dilution improve with volume Moderate Requires data infrastructure [59, 80]
Low-volume setting Lower Learning and cost dilution are limited Low Higher per-case cost [46, 47]
High functional expectations Uncertain Subgroups may benefit, but expectations can amplify dissatisfaction Low Selection criteria remain immature [14, 36]
Need for quantitative balance assessment Conditional Reproducible gap data can inform component and soft-tissue decisions Low Benefit depends on target, alignment philosophy, and surgeon response [26, 35, 94, 96]
Cost-constrained health system Conditional Value depends on measurable offsets Low to moderate Capital and disposable costs dominate [49, 86, 87]

Fig. 2.

Fig. 2

Decision framework for selective RA-TKA use. The framework begins with patient complexity, deformity, anatomy, expectations, and risk profile; then incorporates platform availability, surgeon and team experience, case volume, cost structure, and local outcomes. Selective use is favored when expected technical value and institutional capability are high

Limitations of current evidence

The current evidence is limited by heterogeneity of robotic systems, alignment targets, measurement methods, and surgeon experience. A CT-based robotic-arm study, an imageless handheld study, and a gap-tensioning study may all be labeled RA-TKA. These interventions differ materially. Systematic reviews that pool them can identify broad patterns, especially improved radiographic precision; platform-specific recommendations require platform-specific evidence [18, 22, 75].

Methodological reporting compounds this heterogeneity. Couch et al. reviewed 134 primary RA-TKA studies and found that only 23.9% reported all variables in the technique domain. Alignment philosophy was reported in 79.1%, coronal boundaries in 68.7%, sagittal boundaries in 42.5%, and quantitative soft-tissue balancing goals in 47.8%; surgeon experience and case volume were reported in 50.0% and 16.4%, respectively [98]. Omission of these variables limits reproducibility and makes causal attribution difficult when technology, alignment philosophy, balancing method, and surgeon experience change together. A radiographic or clinical difference can otherwise be assigned to the robotic platform even when the operative strategy differed materially between groups.

Follow-up is another major limitation. Many trials report early recovery, 6-month outcomes, or 1-year PROMs. Revision and survivorship advantages require much longer observation, especially because conventional TKA already has high durability. Registry studies provide scale but may lack details about platform, alignment target, surgeon experience, balance strategy, and patient-reported outcomes [44–45, 74].

Confounding is substantial. Centers adopting robotics may also adopt ERAS pathways, outpatient protocols, regional anesthesia, standardized pain regimens, and structured follow-up. Early adopters may have higher volume, better resources, and stronger interest in arthroplasty technology. Industry sponsorship and selective reporting can also influence study framing. Reviews of media claims, statistical fragility, and spin in RA-TKA evidence reinforce the need for cautious interpretation [92–93].

PROM reporting remains inconsistent. Many studies report means without MCID, patient acceptable symptom state, responder analyses, or baseline-adjusted subgroup analysis. Outcome instruments also vary, making comparisons across studies difficult. Economic evidence is similarly context dependent, with results driven by assumptions about revision reduction, volume, LOS, post-acute care, and device cost. These limitations should temper procurement, consent, and publication language.

Another limitation is publication timing. Robotic platforms, software versions, cutting tools, planning interfaces, and alignment philosophies evolve during the same period in which studies are recruiting and publishing. A study may accurately describe outcomes for a platform configuration that has already changed by the time the manuscript is read. The evidence remains relevant when readers check whether the platform, software, and workflow match their own practice.

Future research priorities

Future research should prioritize long-term registry linkage with platform-specific identifiers, defined alignment targets and boundaries, planned and achieved component position, intraoperative balance data, surgeon experience, and PROMs. Trials should be powered for patient-centered outcomes and should report MCID, patient acceptable symptom state, revision, reoperation, instability, complications, opioid use, LOS, discharge destination, and cost. Randomized registry-nested designs can combine randomized treatment assignment with long-term follow-up [35, 81].

For RA-TKA technique reporting, a minimum dataset should state the robotic platform and clinically relevant software version; implant and constraint; named alignment philosophy with coronal, sagittal, and rotational target boundaries; planned and achieved component position; balancing method; measurement force or other standardized measurement conditions; medial and lateral gaps or laxity at defined flexion angles before and after balancing; the intended gap configuration; the structure released, sequence, and extent of each release; any bone recut or component adjustment; insert thickness; surgeon experience, case volume, and learning-curve phase; and clinical outcomes linked to MCID or patient acceptable symptom state together with instability and revision outcomes [98–100]. An alignment label alone is insufficient for reproducibility when the same label can be reached through different component and gap configurations [99].

Subgroup analyses should be prespecified. The field needs to know whether RA-TKA adds greater value in severe deformity, complex anatomy, high-risk patients, high-demand patients, stiffness, obesity, post-traumatic anatomy, and different alignment phenotypes. Comparisons should separate image-based from imageless systems, handheld from robotic-arm systems, and mechanical from functional or kinematic targets. Studies should also prespecify alignment philosophy and balancing strategy; when sample size and design permit, technology × strategy interaction analyses can test whether the effect of robotics varies across alignment or balancing approaches. The RASKAL factorial design illustrates how technology and alignment effects can be estimated separately within one trial [35].

Economic evaluations should be performed across different healthcare systems with explicit assumptions. They should include capital and maintenance cost, disposable cost, imaging, operative time, LOS, post-acute care, readmissions, complications, revision, quality-adjusted life years, and opportunity cost. Because value depends heavily on local volume and reimbursement, multicountry sensitivity analyses are more useful than single-country conclusions [49, 85–87].

Future comparative reports should connect each observed outcome to the operative pathway that could plausibly produce it: target selection, measurement method, execution accuracy, soft-tissue intervention, and resulting component and gap state. This structure permits separate interpretation of technology effects, alignment or balancing strategy effects, and their interaction. The proposed dataset is an evidence-informed reporting framework derived from documented gaps in the current literature [98–100].

Conclusions

RA-TKA reliably improves technical precision and reduces radiographic outliers. Evidence for durable patient-level superiority remains mixed across pain, function, satisfaction, complications, revision, survivorship, and cost-effectiveness. Robotic assistance provides quantitative measurement and execution support within the broader balancing process. Clinical value depends on a defensible alignment and balance target, sequential reassessment, and surgeon-guided response to the measured soft-tissue state, together with patient selection, platform, team experience, institutional volume, and cost structure. Future studies should prioritize clinically meaningful endpoints, long-term survivorship, revision risk, PROMs, cost-effectiveness, and detailed reporting of alignment and balancing strategy.

Author contributions

Conceptualization, J. S., M.Ł., A.S.; K.B. methodology, J.S., A.S.; software, J.S., K.B.; validation, J.S.; A.S. formal analysis, M.Ł., A.S.; investigation, J.S., K.B.;resources, J.S.; M.Ł. data curation, J.S., A.S; writing—original draft preparation, M.Ł., J.S.;writing—review and editing, M.Ł., A.S.; visualization, J.S. ; K.B. supervision, A.S., K.B; project administration, M.Ł,, J.S; funding acquisition, N/A. All authors have read and agreed to thepublished version of the manuscript.

Funding

No external funding is declared.

Data availability

No datasets were generated or analysed during the current study.

Declarations

Competing interests

The authors declare no competing interests.

Ethical approval

Not applicable. This review used published literature only and did not involve human participants, patient data, or biological material.

Consent to participate

Not applicable.

Consent for publication

Not applicable.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Evans JT, Walker RW, Evans JP, Blom AW, Sayers A, Whitehouse MR (2019) How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up. Lancet (London England). 10.1016/S0140-6736(18)32531-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Li J, Guan T, Zhai Y, Zhang Y (2024) Risk factors of chronic postoperative pain after total knee arthroplasty: a systematic review. J Orthop Surg Res. 10.1186/s13018-024-04778-w [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Muertizha M, Cai X, Ji B, Aimaiti A, Cao L (2022) Factors contributing to 1-year dissatisfaction after total knee arthroplasty: a nomogram prediction model. J Orthop Surg Res. 10.1186/s13018-022-03205-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Fu X, She Y, Jin G, Liu C, Liu Z, Li W, Jin R (2024) Comparison of robotic-assisted total knee arthroplasty: an updated systematic review and meta-analysis. J robotic Surg. 10.1007/s11701-024-02045-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Fozo ZA, Ghazal AH, Hesham Gamal M, Matar SG, Kamal I, Ragab KM (2023) A Systematic Review and Meta-Analysis of Conventional Versus Robotic-Assisted Total Knee Arthroplasty. Cureus. 10.7759/cureus.46845 [DOI] [PMC free article] [PubMed]
  • 6.Ruangsomboon P, Ruangsomboon O, Pornrattanamaneewong C, Narkbunnam R, Chareancholvanich K (2023) Clinical and radiological outcomes of robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Acta Orthop. 10.2340/17453674.2023.9411 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Mert Ü, Khasawneh MY, Ghandour M, Al Zuabi A, Horst K, Hildebrand F et al (2025) Comparative Efficacy and Precision of Robot-Assisted vs. Conventional Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. J Clin Med. 10.3390/jcm14093249 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Yue HY, Ding GQ, Li HX, Zeng J, Jiang XD, Zhu ZD, Jiang H (2025) Does Robotic-Assisted Total Knee Arthroplasty Improve Outcomes of Adult Osteoarthritis Patients-A Systematic Review and Trial Sequential Meta-Analysis. Orthop Surg. 10.1111/os.70007 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Klincke V, Huyghe R, Vermue H, Martens M, Victor J (2026) Robot-assisted total knee arthroplasty demonstrates superior radiological but comparable clinical outcomes compared to conventional techniques: A meta-analysis of prospective studies. Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA. 10.1002/ksa.70007 [DOI] [PubMed]
  • 10.Yadavalli S, Sharma P (2026) Precision vs. paradox: A systematic review and meta-analysis of clinical outcomes, radiographic accuracy and cost-effectiveness in robotic-assisted total knee arthroplasty (2015–2025). J rob. surg. 10.1007/s11701-026-03279-8 [DOI] [PubMed]
  • 11.Mostafa O, Malik M, Qayum K, Ishaq U, Khan AM, Wasim AS, Alsoud Z, Quraishi S (2025) Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of alignment accuracy and clinical outcomes. Annals of medicine and surgery (2012). 10.1097/MS9.0000000000002919 [DOI] [PMC free article] [PubMed]
  • 12.García-Sanz F, Sosa-Reina MD, Jaén-Crespo G, González-de-la-Flor Á, Villafañe JH, Romero-Morales C (2025) Redefining Knee Arthroplasty: Does Robotic Assistance Improve Outcomes Beyond Alignment? An Evidence-Based Umbrella Review. J clinic. med. 10.3390/jcm14082588 [DOI] [PMC free article] [PubMed]
  • 13.Tian XQ, Ji H, Xiang YH, Jia GA (2025) [Umbrella review of robotic-assisted total knee arthroplasty versus conventional total knee arthroplasty:surgical outcomes]. Zhongguo gu shang = China J Orthop Traumatol. 10.12200/j.issn.1003-0034.20250265 [DOI] [PubMed] [Google Scholar]
  • 14.Hoveidaei AH, Esmaeili S, Ghaseminejad-Raeini A, Pirahesh K, Fallahi MS, Sandiford NA, Citak M (2024) Robotic assisted Total Knee Arthroplasty (TKA) is not associated with increased patient satisfaction: a systematic review and meta-analysis. Int Orthop. 10.1007/s00264-024-06206-4 [DOI] [PubMed] [Google Scholar]
  • 15.Clement ND, Galloway S, Baron YJ, Smith K, Weir DJ, Deehan DJ (2023) Robotic Arm-assisted versus Manual (ROAM) total knee arthroplasty: a randomized controlled trial. bone joint J. 10.1302/0301-620X.105B9.BJJ-2023-0006.R3 [DOI] [PubMed] [Google Scholar]
  • 16.Ajekigbe B, Ramaskandhan J, Clement N, Galloway S, Gabrov N, Smith K, Weir D, Deehan D (2024) Robotic-arm assisted versus manual total knee arthroplasty: Functional gait analysis from a randomised controlled trial. J Biomech. 10.1016/j.jbiomech.2024.112112 [DOI] [PubMed] [Google Scholar]
  • 17.Clement ND, Galloway S, Baron J, Smith K, Weir DJ, Deehan DJ (2024) Patients undergoing robotic arm-assisted total knee arthroplasty have a greater improvement in knee-specific pain but not in function. bone joint J. 10.1302/0301-620X.106B5.BJJ-2023-1196.R1 [DOI] [PubMed] [Google Scholar]
  • 18.Vermue H, Batailler C, Monk P, Haddad F, Luyckx T, Lustig S (2023) The evolution of robotic systems for total knee arthroplasty, each system must be assessed for its own value: a systematic review of clinical evidence and meta-analysis. Arch Orthop Trauma Surg. 10.1007/s00402-022-04632-w [DOI] [PubMed] [Google Scholar]
  • 19.Walgrave S, Oussedik S (2023) Comparative assessment of current robotic-assisted systems in primary total knee arthroplasty. Bone joint open. 10.1302/2633-1462.41.BJO-2022-0070.R1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Siddiqi A, Horan T, Molloy RM, Bloomfield MR, Patel PD, Piuzzi NS (2021) A clinical review of robotic navigation in total knee arthroplasty: historical systems to modern design. EFORT open reviews. 10.1302/2058-5241.6.200071 [DOI] [PMC free article] [PubMed]
  • 21.Vermue H, Batailler C, Lustig S (2026) Differences between image-based and imageless robotics for total knee arthroplasty - an overview. J Orthop. 10.1016/j.jor.2025.08.045 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.El Motassime A, Tanzi Germani G, Sangaletti R, Andriollo L, Cinelli V, Benazzo F, Rossi SMP (2026) Imageless robotic assisted TKA: a systematic review. J Orthop. 10.1016/j.jor.2026.02.046 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Narkbunnam R, Chorunchan Y, Chareancholvanich K, Achawakulthep C, Awirotananon K, Pornrattanamaneewong C (2026) Imageless and image-based robotic-assisted total knee arthroplasty achieve equivalent radiographic accuracy: A randomised controlled trial. Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA. 10.1002/ksa.70123 [DOI] [PMC free article] [PubMed]
  • 24.Li Z, Chen X, Wang X, Zhang B, Wang W, Fan Y et al (2022) HURWA robotic-assisted total knee arthroplasty improves component positioning and alignment - A prospective randomized and multicenter study. J Orthop translation. 10.1016/j.jot.2021.12.004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Möller A, Kasabji F, Fischer M, Schoon J, Hofer A, Wassilew GI, Reichert JC (2025) Improved surgical accuracy in total knee arthroplasty using the ROSA® knee system: A randomised-controlled unblinded trial. Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA. 10.1002/ksa.70197 [DOI] [PMC free article] [PubMed]
  • 26.Lizcano JD, Restrepo S, Tarabichi S, Gold PA, Saxena A, Austin MS (2026) Does the Use of a Robotic Gap-tensioning System Improve Functional Outcomes After TKA? A Randomized Clinical Trial. Clinical orthopaedics and related research. 10.1097/CORR.0000000000003734 [DOI] [PubMed]
  • 27.Lychagin AV, Gritsyuk AA, Elizarov MP, Gritsuk AA, Gavlovsky MY, Tomboidi KK, Kalinsky EB, Rosenberg N (2025) Mechanical Versus Restrictive Kinematic Alignment in Robotic-Assisted Total Knee Arthroplasty: A Randomized Controlled Trial. Diagnostics, Basel, Switzerland. 10.3390/diagnostics15192524 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Jhurani A, Agarwal P, Ardawatia G, Sahni H, Srivastava M (2025) Functional and radiological outcomes of computer-assisted and handheld robotic total knee arthroplasty: A prospective randomised study. Knee. 10.1016/j.knee.2025.05.003 [DOI] [PubMed] [Google Scholar]
  • 29.Sah AP, Womack JL, Kissin YD, Debbi EM, Cotter TR (2026) Implant-agnostic, handheld wireless robotics: multicenter efficiency and learning curve for total knee arthroplasty. J robotic Surg. 10.1007/s11701-026-03242-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Mannan A, Vun J, Lodge C, Eyre-Brook A, Jones S (2018) Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: A systematic review and meta-analysis. surgeon: J Royal Colleges Surg Edinb Irel. 10.1016/j.surge.2017.12.003 [DOI] [PubMed] [Google Scholar]
  • 31.Vaidya NV, Deshpande AN, Panjwani T, Patil R, Jaysingani T, Patil P (2022) Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial. Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA. 10.1007/s00167-020-06353-2 [DOI] [PubMed]
  • 32.Thiengwittayaporn S, Uthaitas P, Senwiruch C, Hongku N, Tunyasuwanakul R (2021) Imageless robotic-assisted total knee arthroplasty accurately restores the radiological alignment with a short learning curve: a randomized controlled trial. Int Orthop. 10.1007/s00264-021-05179-y [DOI] [PubMed] [Google Scholar]
  • 33.Geng X, Dong Z, Chen J, Tian M, Wang Y, Ren Y et al (2025) Better radiological outcomes but equal clinical function of a novel knee arthroplasty robot system: a prospective randomized controlled trial. Int Orthop. 10.1007/s00264-025-06523-2 [DOI] [PubMed] [Google Scholar]
  • 34.Migliorini F, Pilone M, Schäfer L, Simeone F, Bell A, Maffulli N (2024) Functional alignment in robotic-assisted total knee arthroplasty: a systematic review. Arch Orthop Trauma Surg. 10.1007/s00402-023-05195-0 [DOI] [PubMed] [Google Scholar]
  • 35.MacDessi SJ, Wernecke GC, Ghadirinejad K, Wood JA, Holder C, Lorimer M et al (2026) Robotic-assisted surgery and functional alignment in total knee arthroplasty: the RASKAL registry-nested 2 × 2 factorial randomized trial. bone joint J. 10.1302/0301-620X.108B.BJJ-2025-1472.R2 [DOI] [PubMed] [Google Scholar]
  • 36.Clement ND, Galloway S, Baron J, Smith K, Weir DJ, Deehan DJ (2024) Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: Secondary analysis of data from a randomised controlled trial. Knee. 10.1016/j.knee.2024.03.005 [DOI] [PubMed] [Google Scholar]
  • 37.Xu J, Li L, Fu J, Xu C, Ni M, Chai W et al (2022) Early Clinical and Radiographic Outcomes of Robot-Assisted Versus Conventional Manual Total Knee Arthroplasty: A Randomized Controlled Study. Orthopaedic surgery. 10.1111/os.13323 [DOI] [PMC free article] [PubMed]
  • 38.Xu Z, Li H, Liu Z, Li J, Zhang J, Wang M, Zhang Y (2022) Robot-assisted surgery in total knee arthroplasty: trauma maker or trauma savior? A prospective, randomized cohort study. Burns & trauma. 10.1093/burnst/tkac034 [DOI] [PMC free article] [PubMed]
  • 39.Maman D, Steinfeld Y, Berkovich Y (2026) National evidence linking robotic total knee arthroplasty to reduced 90-day readmissions, complications, and readmission costs. Arthroplasty (London Engl. 10.1186/s42836-026-00373-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Nogalo C, Meena A, Abermann E, Fink C (2023) Complications and downsides of the robotic total knee arthroplasty: a systematic review. Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA. 10.1007/s00167-022-07031-1 [DOI] [PMC free article] [PubMed]
  • 41.Peñaherrera-Carrillo C, Cabrera-Ávila MS, Quintero-Quintero M, Aranda VC, Villaseñor CJP, Suarez-Ahedo C (2026) Periprosthetic fractures associated with pin placement in robot- or navigation-assisted total knee arthroplasty: a systematic review and meta-analysis. J robotic Surg. 10.1007/s11701-026-03346-0 [DOI] [PubMed] [Google Scholar]
  • 42.Wang JC, Piple AS, Hill WJ, Chen MS, Gettleman BS, Richardson M, Heckmann ND, Christ AB (2022) Computer-Navigated and Robotic-Assisted Total Knee Arthroplasty: Increasing in Popularity Without Increasing Complications. The Journal of arthroplasty. 10.1016/j.arth.2022.06.014 [DOI] [PubMed]
  • 43.Chen J, Loke RWK, Lim KK, Tan BWL (2025) Survivorship in robotic total knee arthroplasty compared with conventional total knee arthroplasty: A systematic review and meta-analysis. Arthroplasty (London, England) 10.1186/s42836-025-00304-3 [DOI] [PMC free article] [PubMed]
  • 44.Pius AK, Sporer SM, Sterling O, De M, Jahan M, Browne JA, Springer BD, Huddleston JI (2025) Navigated and Robotic Total Knee Arthroplasty Do Not Confer Improved 5-Year Survivorship Compared to Conventional Total Knee Arthroplasty: An Analysis From the American Joint Replacement Registry. J Arthroplast. 10.1016/j.arth.2025.03.047 [DOI] [PubMed] [Google Scholar]
  • 45.Kirchner GJ, Stambough JB, Jimenez E, Nikkel LE (2024) Robotic-assisted TKA is Not Associated With Decreased Odds of Early Revision: An Analysis of the American Joint Replacement Registry. Clinical orthopaedics and related research. 10.1097/CORR.0000000000002783 [DOI] [PMC free article] [PubMed]
  • 46.Rajan PV, Khlopas A, Klika A, Molloy R, Krebs V, Piuzzi NS (2022) The Cost-Effectiveness of Robotic-Assisted Versus Manual Total Knee Arthroplasty: A Markov Model-Based Evaluation. J Am Acad Orthop Surg. 10.5435/JAAOS-D-21-00309 [DOI] [PubMed] [Google Scholar]
  • 47.Vermue H, Tack P, Gryson T, Victor J (2021) Can robot-assisted total knee arthroplasty be a cost-effective procedure? A Markov decision analysis. Knee. 10.1016/j.knee.2021.02.004 [DOI] [PubMed] [Google Scholar]
  • 48.Zhang JJY, Chen JY, Tay DKJ, Pang HN, Yeo SJ, Liow MHL (2023) Cost-Effectiveness of Robot-Assisted Total Knee Arthroplasty: A Markov Decision Analysis. J Arthroplast. 10.1016/j.arth.2023.02.022 [DOI] [PubMed] [Google Scholar]
  • 49.Sagoo GS, Clement ND, Gil-Rojas Y, Bhattarai N, Galloway S, Baron JB et al (2025) Cost-effectiveness analysis of robotic-arm assisted versus manual total knee arthroplasty in the UK. Bone joint open. 10.1302/2633-1462.66.BJO-2024-0274 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Matsumoto K, Ishimaru D, Sohmiya K, Terabayashi N (2025) Benefits of Image-Free Robotic-Assisted Total Knee Arthroplasty in Early Postoperative Recovery and Tibial Alignment Accuracy. Cureus. 10.7759/cureus.92044 [DOI] [PMC free article] [PubMed]
  • 51.Neira I, Llopis R, Cuadrado L, Fernández D, Galdrán J, Forriol F (2026) Early clinical benefits of robot-assisted versus manual total knee arthroplasty: A randomized controlled trial. Knee. 10.1016/j.knee.2026.104457 [DOI] [PubMed] [Google Scholar]
  • 52.Gonzalez MR, Lim PL, Chen AF, Melnic CM, Bedair HS (2025) Comparing Rates of Minimal Clinically Important Difference Between Manual and Robotic-Assisted Total Knee Arthroplasty. J Arthroplast. 10.1016/j.arth.2024.08.039 [DOI] [PubMed] [Google Scholar]
  • 53.Buchlak QD, Clair J, Esmaili N, Barmare A, Chandrasekaran S (2022) Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review. Eur J Orthop Surg &. 10.1007/s00590-021-03059-0. traumatology: orthopedie traumatologie [DOI] [PubMed] [Google Scholar]
  • 54.Bulzacki-Bogucki BD, Digennaro V, Ferri R, Panciera A, Cecchin D, Colangelo A, Benvenuti L, Faldini C (2025) Robotic-assisted total knee arthroplasty: Promise or parity in long-term outcomes? Musculoskeletal surgery. 10.1007/s12306-025-00922-9 [DOI] [PubMed]
  • 55.Zaidi F, Bolam SM, Goplen CM, Yeung T, Hanlon M, Munro JT, Besier TF, Monk AP (2026) Have we come to the end of the patient-reported outcome measure (PROM)? wearable sensors highlight improved rate of recovery and range of motion following robotic-assisted total knee arthroplasty that are overlooked by conventional PROMs. bone joint J. 10.1302/0301-620X.108B4.BJJ-2024-1236.R2 [DOI] [PubMed] [Google Scholar]
  • 56.Weissman B, Ma TY, Shen K, Chowdhury S, Speer D, Lambroussis C (2025) A Comparison of Operative Time Between Robotic Surgical Assistant (ROSA) and MAKO Robotic-Assisted Total Knee Arthroplasty: A Meta-Analysis. Cureus. 10.7759/cureus.92933 [DOI] [PMC free article] [PubMed]
  • 57.Abdel Khalik H, Abesteh J, Aldawodi M, Khanna V, Adili A (2025) The learning curve of robotic-assisted total knee arthroplasty: a systematic review and meta-analysis. J robotic Surg. 10.1007/s11701-025-02576-y [DOI] [PubMed] [Google Scholar]
  • 58.Barahona M, Bustos F, Hinzpeter J, Urroz F, Barrientos C, Infante CA, Barahona MA (2025) Evaluation of the Learning Curve in Robotic-Assisted Total Knee Arthroplasty: A Time-Series Analysis of Surgical Time. Cureus. 10.7759/cureus.84120 [DOI] [PMC free article] [PubMed]
  • 59.Haikal ER, Zaniletti I, Katchis CS, Ang BK, Lafage V, Slover JD (2026) Institutional Surgical Volume and Operative Efficiency in Robotic-Assisted Total Knee Arthroplasty: An Analysis From the American Joint Replacement Registry. The Journal of arthroplasty. 10.1016/j.arth.2026.04.004 [DOI] [PubMed]
  • 60.Kwak SG, Kwon JB, Kim Seo HC, Choi WK (2025) Perioperative blood loss of surgical techniques designed for alignment that do not violate intramedullary cavity of the femur in patients with total knee arthroplasty: A systematic review and meta-analysis. Medicine. 10.1097/MD.0000000000042722 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Lai YH, Xu H, Su Q, Wan XF, Yuan MC, Zhou ZK (2022) Effect of tourniquet use on blood loss, pain, functional recovery, and complications in robot-assisted total knee arthroplasty: a prospective, double-blinded, randomized controlled trial. J Orthop Surg Res. 10.1186/s13018-022-02992-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Maman D, Steinfeld Y, Berkovich Y (2026) In-hospital outcomes and hospital charges after robotic-assisted versus conventional total knee arthroplasty: A 2016–2022 Nationwide Inpatient Sample study. PLoS ONE. 10.1371/journal.pone.0346031 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Katchis C, Ang B, Haikal E, Patel K, Lafage R, Lafage V, Slover J (2025) Impact of robotic assistance on hospital stay direct costs of total knee arthroplasty. J robotic Surg. 10.1007/s11701-025-02828-x [DOI] [PubMed] [Google Scholar]
  • 64.Hay PC, Collins W, Sidhu VS, Alexander K, Fritsch BA, Gupta S et al (2025) Are Rates of Inpatient Rehabilitation Reduced for Robotic Assisted Total Knee Arthroplasty Compared With Computer Navigated Total Knee Arthroplasty? ANZ journal of surgery. 10.1111/ans.70241 [DOI] [PMC free article] [PubMed]
  • 65.Ng EC, Xu S, Liu XE, Lim JBT, Liow MHL, Pang HN et al (2024) Enhanced recovery after surgery day surgery for MAKO® robotic-arm assisted TKA; better outcome for patients, improved efficiency for hospitals. J Orthop. 10.1016/j.jor.2024.05.013 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66.Idrees MA, Ibrahim S, Ibrahim M (2026) Robotic-Assisted Versus Conventional Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of Randomized and Quasi-randomized Controlled Trials Evaluating Perioperative and Radiographic Outcomes. Cureus. 10.7759/cureus.106394 [DOI] [PMC free article] [PubMed]
  • 67.Aggarwal VA, Sun J, Sambandam SN (2024) Outcomes following robotic assisted total knee arthroplasty compared to conventional total knee arthroplasty. Arch Orthop Trauma Surg. 10.1007/s00402-024-05231-7 [DOI] [PubMed] [Google Scholar]
  • 68.Finch D, Mazzocco J, Coden GS, Travers HI, Mattingly DA (2026) National Trends in Use and Complications of Cemented, Cementless, Manual, and Robotic-Assisted Total Knee Arthroplasty: 2016–2022. J Knee Surg. 10.1055/a-2712-4129 [DOI] [PubMed] [Google Scholar]
  • 69.Weaver DJ, Deshmukh S, Bashyal R, Bagaria V (2024) Complications and Learning Curve Associated with an Imageless Burr-Based (CORI) Robotic-Assisted Total Knee Arthroplasty System: Results from First 500 Cases. Indian J Orthop. 10.1007/s43465-024-01200-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Dragosloveanu S, Petre MA, Capitanu BS, Dragosloveanu CDM, Cergan R, Scheau C (2023) Initial Learning Curve for Robot-Assisted Total Knee Arthroplasty in a Dedicated Orthopedics Center. J Clinic. Med. 10.3390/jcm12216950 [DOI] [PMC free article] [PubMed]
  • 71.Howell CC, Witvoet S, Scholl L, Coppolecchia A, Bhowmik-Stoker M, Chen AF (2025) Postoperative Complications and Readmission Rates in Robotic-Assisted Versus Manual Total Knee Arthroplasty: Large, Propensity Score-Matched Patient Cohorts. J Am Acad Orthop Surg. 10.5435/JAAOS-D-23-01117 [DOI] [PubMed] [Google Scholar]
  • 72.Gordon AM, Smitterberg CW, Jacofsky D, Mont MA (2026) Robotic-assisted total knee arthroplasty associated with lower odds of vascular injury: A retrospective cohort analysis. J Clin Orthop trauma. 10.1016/j.jcot.2026.103452 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 73.Tompkins GS, Sypher KS, Griffin TM, Duwelius PD (2022) Can a Reduction in Revision Rates Make Robotic Total Knee Arthroplasty Cost Neutral With Manual Total Knee Arthroplasty at Ten-Year Follow-Up? An Episode Cost Analysis. The Journal of arthroplasty. 10.1016/j.arth.2021.10.030 [DOI] [PubMed]
  • 74.Hoskins W, Gusho C, Bingham R, Du P, Oakey H, Vince KG, McAuliffe M (2026) Does Transitioning to Robotic-Assisted Total Knee Arthroplasty Change Surgeon Revision Risk or Failure Modes? A Baseline Comparative Analysis Before and After Robotic Adoption. JB & JS. open access. 10.2106/JBJS.OA.26.00127 [DOI] [PMC free article] [PubMed]
  • 75.Patel RD, Ganesaraja P, Sugand K, Kanakala S, Gupte I, Namireddy SR, Gill SS (2026) Platform-Specific Learning Curves in Robotic-Assisted Total Knee Arthroplasty: A Systematic Review. Orthop Surg. 10.1111/os.70304 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 76.Pujol O, Minguell J, Pijoan J, Aguilar M, Reverté M, Plomer M, García-Albó E, Joshi N (2025) Learning curve of robotic-assisted total knee arthroplasty: a literature review. J robotic Surg. 10.1007/s11701-025-02597-7 [DOI] [PubMed] [Google Scholar]
  • 77.Neira I, Llopis R, Cuadrado L, Fernández D, Villanueva E, Nuño N, Forriol F (2024) Analysis of the Initial Learning Curve for Robotic-Assisted Total Knee Arthroplasty Using the ROSA® Knee System. J Clinic. Med. 10.3390/jcm13113349 [DOI] [PMC free article] [PubMed]
  • 78.Kubo T, Takahashi T, Kaneda Y, Watanabe K, Shinohara S, Higashi T, Takeshita K (2026) Assessment of surgeon workload using the NASA-TLX during the early introduction of robot-assisted total knee arthroplasty. J Orthop. 10.1016/j.jor.2025.12.055 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 79.Meghpara MM, Goh GS, Magnuson JA, Hozack WJ, Courtney PM, Krueger CA (2023) The Ability of Robot-Assisted Total Knee Arthroplasty in Matching the Efficiency of Its Conventional Counterpart at an Orthopaedic Specialty Hospital. The Journal of arthroplasty. 10.1016/j.arth.2022.07.024 [DOI] [PubMed]
  • 80.Khan ST, Emara AK, Zhou G, Koroukian SM, Piuzzi NS, Cleveland Clinic Adult Reconstruction Research (2025) Robotic-assisted total knee arthroplasty in the USA: Nationwide adoption trends towards 70% by 2030. J Clin Orthop trauma. 10.1016/j.jcot.2025.103069 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 81.MacDessi SJ, Wernecke GC, Bastiras D, Hooper T, Heath E, Lorimer M, Harris I, RASKAL Study Group (2022) Robotic-assisted surgery and kinematic alignment in total knee arthroplasty (RASKAL study): a protocol of a national registry-nested, multicentre, 2×2 factorial randomised trial assessing clinical, intraoperative, functional, radiographic and survivorship outcomes. BMJ open. 10.1136/bmjopen-2021-051088 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 82.Leal J, Cochrane NH, Kim BI, Holland CT, Hallows R, Seyler T (2024) A Cost Analysis of Traditional Versus Robotic Total Knee Arthroplasty Performed With an Imageless, Second-generation Robotic System. Orthopedics. 10.3928/01477447-20240809-05 [DOI] [PubMed]
  • 83.Steffens D, Karunaratne S, McBride K, Gupta S, Horsley M, Fritsch B (2022) Implementation of robotic-assisted total knee arthroplasty in the public health system: a comparative cost analysis. Int Orthop. 10.1007/s00264-021-05203-1 [DOI] [PubMed] [Google Scholar]
  • 84.Shah R, Diaz A, Phieffer L, Quatman C, Glassman A, Hyer JM, Tsilimigras D, Pawlik TM (2021) Robotic total knee arthroplasty: A missed opportunity for cost savings in Bundled Payment for Care Improvement initiatives? Surgery. 10.1016/j.surg.2020.12.046 [DOI] [PubMed]
  • 85.Tiwari A, Bagaria V (2026) Global adoption of robotic-assisted total knee arthroplasty: a review of trends and drivers from 2020 to 2025. J robotic Surg. 10.1007/s11701-026-03220-z [DOI] [PubMed] [Google Scholar]
  • 86.Ruangsomboon P, Ruangsomboon O, Isaranuwatchai W, Zywiel MG, Naimark DM (2025) Cost-effectiveness of robotic-assisted versus conventional total knee arthroplasty: an analysis from a middle income country. Acta Orthop. 10.2340/17453674.2025.44753 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 87.Goudazi Z, Jafari M, Kiyaei A, Ravangard R, Hashemi SA, Keshavarz K (2025) Cost-effectiveness analysis of robotic-arm assisted total knee arthroplasty (TKA) versus conventional TKA in Iranian population. Health Econ Rev. 10.1186/s13561-025-00648-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 88.Abdel Khalik H, Aldawodi M, Lameire DL, Wood TJ, Khanna V, Adili A (2026) Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review. J Orthop. 10.1016/j.jor.2026.02.017 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 89.Olaonipekun E, Movahedi K, Vivekanantha P, Kooner P, Ekhtiari S (2026) Robotic-Assisted Total Knee Arthroplasty in Complex Primary and Revision Cases: A Systematic Review. Curr Rev Musculoskelet Med. 10.1007/s12178-026-10026-x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 90.Soundarrajan D, Kumar KM, Singh R, Rajasekaran RB, Palanisami D, Natesan R, Rajasekaran S (2025) Imageless robotic-assisted total knee arthroplasty allows intra-articular correction of severe extra-articular deformities using functional alignment and desired under-correction. Int Orthop. 10.1007/s00264-025-06563-8 [DOI] [PubMed] [Google Scholar]
  • 91.Young SW, Tay ML, Kawaguchi K, van Rooyen R, Walker ML, Farrington WJ, Bayan A (2025) The John N. Insall Award: Functional Versus Mechanical Alignment in Total Knee Arthroplasty: A Randomized Controlled Trial. J Arthroplast. 10.1016/j.arth.2025.02.065 [DOI] [PubMed] [Google Scholar]
  • 92.Ekhtiari S, Sun B, Sidhu R, Ade-Conde AM, Chaudhry H, Tomescu S, Ravi B, Mundi R (2024) Evidence Versus Frenzy in Robotic Total Knee Arthroplasty: A Systematic Review Comparing News Media Claims to Randomized Controlled Trial Evidence. The Journal of bone and joint surgery. Am volume. 10.2106/JBJS.24.00264 [DOI] [PubMed] [Google Scholar]
  • 93.Abdel Khalik H, Abesteh J, Khan M, Khanna V, Adili A (2025) Continuous outcomes of robotic-assisted total knee arthroplasty trials are statistically fragile. Eur J Orthop Surg &. 10.1007/s00590-025-04486-z. traumatology: orthopedie traumatologie [DOI] [PubMed] [Google Scholar]
  • 94.Orsi AD, Coffey S, Slotkin E, Gill P, Lehman A, Lawrence J, Plaskos C, Keggi J (2025) Soft tissue balance profiles differ between manual and robotically assessed gaps in total knee arthroplasty. Int J Med Rob Comput Assist Surg. 10.1002/rcs.70124 [DOI] [PubMed] [Google Scholar]
  • 95.Sakai S, Nakamura S, Maeda T, Kuriyama S, Nishitani K, Morita Y, Morita Y, Yamawaki Y, Shinya Y, Matsuda S (2024) Medial soft tissue release is also related to the anterior stability of cruciate-retaining total knee arthroplasty: a cadaveric study. Knee Surgery & Related Research. 10.1186/s43019-024-00233-6 [DOI] [PMC free article] [PubMed]
  • 96.MacDessi SJ, Wood JA, Diwan A, Harris IA, SENSOR BALANCE Study Group (2022) Intraoperative pressure sensors improve soft-tissue balance but not clinical outcomes in total knee arthroplasty: a multicentre randomized controlled trial. Bone Joint J. 10.1302/0301-620X.104B5.BJJ-2021-1299.R2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 97.Gurbuz S, Ayaz MB, Igde N, Bahar H, Keskin A, Gurbuz H (2026) Optimizing medial release sequence in varus knee arthroplasty: a stepwise approach. Eur Archives Med Res. 10.14744/eamr.2025.24582 [DOI] [Google Scholar]
  • 98.Couch BK, Pfeil AN, Hryc CF, LeBrun DG, Ihekweazu UN (2026) Alignment boundaries and soft tissue balancing goals are inconsistently reported in robotic-assisted total knee arthroplasty studies: a narrative methodological review. Knee Surgery, Sports Traumatology, Arthroscopy. 10.1002/ksa.70331 [DOI] [PubMed] [Google Scholar]
  • 99.Klasan A, Jeremic D, Neri T, Heyse TJ, Hirschmann MT (2025) Functional alignment in total knee arthroplasty is an umbrella term-A call for better definition and reporting quality! Knee Surg Sports Traumatol Arthrosc. 10.1002/ksa.12774 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 100.MacDessi SJ, Oussedik S, Abdel MP, Victor J, Pagnano MW, Haddad FS (2023) The language of knee alignment: updated definitions and considerations for reporting outcomes in total knee arthroplasty. Bone Joint J. 10.1302/0301-620X.105B2.BJJ-2022-1345 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

No datasets were generated or analysed during the current study.


Articles from Journal of Robotic Surgery are provided here courtesy of Springer

RESOURCES