TABLE 4.
Summary statistics comparing fluence rate between simulation predictions and actinometry measurements by plane height, including means, RMSE, MRBE, and IQR of RBE.
| Statistics | Measurement plane | WR | UR | ||||
|---|---|---|---|---|---|---|---|
| Photopia | Visual | Actinometry | Photopia | Visual | Actinometry | ||
| Mean (W/cm2) | Upper | 0.6 | 0.6 | 1.4 | 49.5 | 76.0 | 41.2 |
| Lower | 3.4 | 3.4 | 2.4 | 0.5 | 0.6 | 3.0 | |
| Both | 2.0 | 2.0 | 1.9 | 25.0 | 38.3 | 22.1 | |
| RMSE (W/cm2) | Upper | 1.9 | 1.7 | – | 37.1 | 62.7 | – |
| Lower | 2.1 | 2.1 | – | 3.3 | 3.2 | – | |
| Both | 2.0 | 1.9 | – | 26.3 | 44.4 | – | |
| MRBE (%) | Upper | −65 | −70 | – | −14 | 34 | – |
| Lower | −5 | −21 | – | −83 | −78 | – | |
| Both | −48 | −52 | – | −26 | 20 | – | |
| IQR of RBE (%) | Upper | 20 | 14 | – | 18 | 38 | – |
| Lower | 63 | 97 | – | 45 | 61 | – | |
| Both | 67 | 51 | – | 70 | 112 | – | |