Skip to main content
. 2006 Feb;74(2):1204–1214. doi: 10.1128/IAI.74.2.1204-1214.2006

TABLE 1.

Comparison of cytokine levels obtained by cytokine antibody array analysis and by ELISA

Cell culture treatment Level (mean ± SD) ofa:
TNF-α
IL-6
IL-10
Cytokine array (odu/mm2) ELISA (pg/ml) Cytokine array (odu/mm2) ELISA (pg/ml) Cytokine array (odu/mm2) ELISA (pg/ml)
None 34 ± 12 54 ± 21 28 ± 14
LPS 79.6 ± 8.2 1,493 ± 42 253.3 ± 32.5 4,244 ± 166 102.3 ± 8.6 1,992 ± 104
FimA 59.6 ± 8.6 996 ± 84 236.4 ± 48.1 3,445 ± 82 84.8 ± 14.2 1,532 ± 98
Live P.g. 102.4 ± 42.8 1,943 ± 238 272.3 ± 26.4 4,435 ± 296 126.9 ± 17.1 2,231 ± 312
a

The cytokine spot intensities in array membranes were quantified by optical density unit (odu) with Bio-Rad VersaDoc Imaging System 3000 and analyzed with Quantity One software. —, no spot detected in the array membrane.