Skip to main content
. 2002 Jul;76(14):7239–7246. doi: 10.1128/JVI.76.14.7239-7246.2002

TABLE 1.

Data collection and image processing

Virus No. of micro- graphs Under- focus (μm)a No. of particlesb Mean correlation coefficientc (SD) Resolution of the map (Å)
AuraT 20 1.90-3.52 3,506 (2,812) 0.397 (0.105) 17.0
AuraB 21 1.46-3.12 1,581 (1,263) 0.454 (0.090) 21.0
a

Determined from the averaged Fourier transform of boxed images.

b

Total number of viral particles boxed from all micrographs. The number of particles used for the three-dimensional reconstruction is given in parentheses.

c

Average real-space correlation coefficient for all particles computed between 165 and 350 Å radii of the final model. The correlation coefficient (CC) was calculated as follows: CC = Σ(ρ1ρ2 − <ρ1><ρ2>)/[Σ(ρ12 − <ρ1>2) Σ(ρ22 − ρ2>2)]0.5. ρ1 and ρ2 refer to the density values of one particle image and its corresponding projection of the three-dimensional reconstruction, respectively. The sum is take over all pixels within the defined radii and <ρ1> and ρ2> refer to the mean values of the image and the corresponding projection of the reconstruction. The standard deviation (SD) of each correlation coefficient is given in parentheses.