Table 2.
Conduction time ranges from start of stimulus used to quantify magnitude changes in fast and slow conducting axons at 22° and 36°C.
| T° & category | Conduction velocity range | Epoch duration |
|---|---|---|
| 22°C fast | 2.2-0.31 m/s | 2.0-14 ms from stim. onset |
| 22°C slow | 0.23-0.06 m/s | 19-70 ms from stim. onset |
| 36°C fast | 3.4-0.58 m/s | 1.3-7.6 ms from stim. onset |
| 36°C slow | 0.44-0.11 m/s | 10-40 ms from stim. onset |