| Algorithm 2: Reading Industrial Parameters |
|
1. Given: process and electrical parameters 2. Initialize: parameter values 3. function Start 4. open OPC UA connection 5. open Modbus TCP connection 6. start Read_Data loop 7. end function 8. function Read_Data 9. while running do 10. read sensors parameters from OPC UA server 11. read electrical parameters from Modbus TCP server 12. end while 13. end function 14. function Update 15. display process parameters in UI 16. display electrical parameters in UI 17. end function 18. function Close_connection 19. running ← false 20. close OPC UA and Modbus TCP connection 21. end function 22. return real-time industrial data |