Skip to main content
. 2005 Sep 2;89(5):3248–3260. doi: 10.1529/biophysj.104.056614

TABLE 2.

Tension (P0), stiffness (Y), and parameters of exponential processes

Parameters Units Type I* Type IIA Type IID Type IIB
P0 kPa 150 ± 20 157 ± 7 157 ± 7 157 ± 4
Y MPa 8.6 ± 0.7 10.0 ± 0.8 9.2 ± 0.6 8.9 ± 0.3
P0/Y %L0 1.74 ± 0.23 1.63 ± 0.10 1.77 ± 0.05 1.80 ± 0.04
H MPa 0.75 2.0 ± 0.1 1.4 ± 0.1 1.1 ± 0.1
A MPa 3.90 9.2 ± 0.7 7.0 ± 0.5 6.0 ± 0.2
B MPa 5.55 7.9 ± 0.7 7.6 ± 0.6 7.7 ± 0.2
C MPa 7.94 6.7 ± 0.5 8.5 ± 0.6 9.4 ± 0.3
2πa s−1 1.90 4.4 ± 0.4 5.50 ± 0.16 6.48 ± 0.15
2πb s−1 4.11 21 ± 2 85 ± 2 168 ± 6
2πc s−1 26.1 238 ± 16 596 ± 23 813 ± 19
2πfmin s−1 6 62.3 ± 2.6 196 ± 3 305 ± 5
N 7 9 26 43
Vu s−1 0.72 1.46 2.25 2.45

These values were obtained at the standard activating condition (5 mM MgATP, 8 mM Pi) at 20°C. The mean ± SE and the number of experiments (number of fiber preparations) are shown by N.

*

From Wang and Kawai (21) except for Vu.

From Andruchov et al. (15) given in fiber length per second; the data were obtained at 22°C in the absence of added Pi, pCa 4.5.