TABLE 1.

Results from the fits to the experimental and simulated anisotropy decays (cf. Fig. 12) using Eq. 6 as the model function, which describes the cone-in-a-cone model

Experiment Simulation
A1 0.34 ± 0.1 (46 ± 4°) 0.39 ± 0.02 (44 ± 1°)
φ1 (0.41 ± 0.03) ns (0.120 ± 0.005) ns
A2 0.067 ± 0.02 (68 ± 1°) 0.32 ± 0.02 (47 ± 1°)
φ2 (0.92 ± 0.2) ns (0.98 ± 0.12) ns
φG 5.0 ns 3.9 ns

Values in parenthesis are the corresponding semicone angles (Eq. 4).