Skip to main content
. 2005 Dec 9;90(5):1687–1696. doi: 10.1529/biophysj.104.055483

TABLE 2.

Flexural rigidity of microtubules obtained with different experimental methods

Microtubules Methods Flexural rigidity (× 10−24 Nm2) Temperature (°C) References
Paclitaxel-free MT (Pure MT)
Buckling force 7.9 33 This work
Buckling force 6.8 (4)
Hydrodynamic flow 8.5 37 (7)
Hydrodynamic flow 35.8 37 (8)
Relaxation (RELAX) 3.7 22–25 (5)
Relaxation (WIGGLE) 4.7 22–25 (5)
Thermal fluctuation 26.0 37 (11)
Thermal fluctuation 4.6 37 (7)
Thermal fluctuation 26.5* 37 (8)
Thermal fluctuation 18.5 (12)
Thermal fluctuation
13.7–27.0*
23
(13)
Paclitaxel-stabilized MT
Buckling force 2.0 33 This work
Buckling force 2.0–22 37 (3)
Buckling force 2.4 (4)
Relaxation (RELAX) 1.0 22–25 (5)
Relaxation (WIGGLE) 1.9 22–25 (5)
Thermal fluctuation 21.5 25 (9)
Thermal fluctuation 32.0 37 (11)
Thermal fluctuation 2.4 37 (7)
*

These values of EI were calculated from the measured values of persistence length, Lp (EI = kBT Lp).