Skip to main content
. 2005 Aug;11(8):1192–1200. doi: 10.1261/rna.2680605

TABLE 1.

Values obtained from the time-resolved FRET data for the RNA-L7Ae complex, and the fitting statistics

Model Parametera Valueb 95% C.I.c χ2
1 Gaussiand r 40.02 39–41.1 11.7
fwhm 25.2 24.1–26.3
2 Gaussian globale r1 43.4 42.1–44.1 10.9
fwhm1 9.8 2.9–16.9
r2 70.6 69.5–71.5
fwhm2 11.6 Fixed
p 0.149 0.072–0.205
2 Gaussianf r1 43.4 42.0–44.2 10.7
fwhm1 8.8 0.0–16.9
r2 69.6 Fixed
fwhm2 14.6 Fixed
p 0.169 0.079–0.221

ar, r1 and r2 are donor-acceptor (D-A) distances and fwhm are full widths at half maxima. p-values are the amplitudes of the long distance, relative to a short distance amplitude of unity.

bAll distances are given in Å.

c95% confidence interval.

dResult of fitting the data for the RNA in the presence of L7Ae to a single Gaussian function of D-A distances.

eResult of fitting the data for the RNA both in the presence and absence of L7Ae globally to two Gaussian functions of D-A distances. The results are only shown for the RNA in the presence of L7Ae. The halfwidth of the longer distance was fixed for this calculation.

fResult of fitting the data for the RNA in the presence of L7Ae to two Gaussian functions of D-A distances. The longer distance and halfwidth were fixed for this calculation.