Skip to main content
. 2026 Aug 4;26:2147. doi: 10.1186/s12903-026-09524-8

Table 3.

Descriptive statistics of tensile bond strength (MPa) for all experimental groups

Group Denture Base Material Reline Material n x̄ ± SD Min Max
1 Conventional PMMA Molloplast-B 10 2.07 ± 0.34 1.67 2.78
2 Conventional PMMA GC Reline II Soft 10 1.76 ± 0.15 1.50 1.95
3 Conventional PMMA Ufi Gel Hard C 10 12.56 ± 2.21 7.62 14.79
4 Milled PMMA Molloplast-B 10 1.97 ± 0.18 1.74 2.26
5 Milled PMMA GC Reline II Soft 10 1.92 ± 0.21 1.48 2.14
6 Milled PMMA Ufi Gel Hard C 10 10.29 ± 1.27 8.95 12.22
7 3D-printed resin Molloplast-B 10 2.16 ± 0.34 1.70 2.85
8 3D-printed resin GC Reline II Soft 10 1.28 ± 0.16 1.07 1.60
9 3D-printed resin Ufi Gel Hard C 10 9.01 ± 1.99 6.08 11.29

SD Standard deviation, x̄ mean