Skip to main content
. 2006 Feb 8;4:10. doi: 10.1186/1476-7120-4-10

Table 1.

Hemodynamic data at baseline, at 180 minutes of coronary occlusion and at 30 minutes of reperfusion, before and during adenosine infusion.

Baseline LAD Occlusion Reperfusion Reperfusion + adenosine
HR (beats·min-1) 124 ± 12 112 ± 24 107 ± 24 106 ± 23
Mean ABP (mmHg) 87 ± 15 87 ± 19 78 ± 19 77 ± 18
LAD Flow (ml·min-1) 21.1 ± 5.3 ------ 21.2 ± 5.7* 19.9 ± 6.0†

Values are mean ± SD. ABP = arterial blood pressure, LAD = left anterior descending coronary artery, HR = heart rate. * p = NS between baseline and reperfusion. † p < 0.05 between baseline and reperfusion + adenosine.