Skip to main content
Biophysical Journal logoLink to Biophysical Journal
. 1983 Dec;44(3):299–304. doi: 10.1016/S0006-3495(83)84303-3

Quantitative pressure injection of picoliter volumes into Limulus ventral photoreceptors.

D W Corson, A Fein
PMCID: PMC1434850  PMID: 6661488

Abstract

Many pharmacological probes must be applied to the interior of cells to produce their effects. Ideally, a method for injecting such materials should be simple, rapid, and independent of the chemical properties of the material to be injected. In addition, one might desire to confirm immediately that an injection occurred and to estimate the volume injected shortly thereafter. We report that these conditions are fulfilled when the injection of materials from micropipettes by pressure pulses is confirmed by visualization of injection-induced disturbances in cells viewed on a video monitor. Volumes of aqueous droplets subsequently injected into a nearby oil pool may be used to estimate the volumes injected into cells. We have obtained a calibration curve for these quantitative estimates of injected volumes by injecting radioactively labeled sulfate into Limulus photoreceptor cells. We find that the estimates are accurate within a range covering one order of magnitude. We assess the sources of systematic and random errors in making these estimates.

Full text

PDF
301

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Brown J. E., Blinks J. R. Changes in intracellular free calcium concentration during illumination of invertebrate photoreceptors. Detection with aequorin. J Gen Physiol. 1974 Dec;64(6):643–665. doi: 10.1085/jgp.64.6.643. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Coles J. A., Brown J. E. Effects of increased intracellular pH-buffering capacity on the light response of Limulus ventral photoreceptor. Biochim Biophys Acta. 1976 Jun 4;436(1):140–153. doi: 10.1016/0005-2736(76)90226-1. [DOI] [PubMed] [Google Scholar]
  3. Fein A., Charlton J. S. Enhancement and phototransduction in the ventral eye of limulus. J Gen Physiol. 1977 May;69(5):553–569. doi: 10.1085/jgp.69.5.553. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Fein A., Charlton J. S. Local adaptation in the ventral photoreceptors of Limulus. J Gen Physiol. 1975 Dec;66(6):823–836. doi: 10.1085/jgp.66.6.823. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Fein A., Corson D. W. Both photons and fluoride ions excite limulus ventral photoreceptors. Science. 1979 Apr 6;204(4388):77–79. doi: 10.1126/science.34877. [DOI] [PubMed] [Google Scholar]
  6. Fein A., Corson D. W. Excitation of Limulus photoreceptors by vanadate and by a hydrolysis-resistant analog of guanosine triphosphate. Science. 1981 May 1;212(4494):555–557. doi: 10.1126/science.6782676. [DOI] [PubMed] [Google Scholar]
  7. Lisman J. E., Brown J. E. Effects of intracellular injection of calcium buffers on light adaptation in Limulus ventral photoreceptors. J Gen Physiol. 1975 Oct;66(4):489–506. doi: 10.1085/jgp.66.4.489. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. McCaman R. E., McKenna D. G., Ono J. K. A pressure system for intracellular and extracellular ejections of picoliter volumes. Brain Res. 1977 Nov 4;136(1):141–147. doi: 10.1016/0006-8993(77)90138-x. [DOI] [PubMed] [Google Scholar]
  9. Sakai M., Swartz B. E., Woody C. D. Controlled micro release of pharmacological agents: measurements of volume ejected in vitro through fine tipped glass microelectrodes by pressure. Neuropharmacology. 1979 Feb;18(2):209–213. doi: 10.1016/0028-3908(79)90063-7. [DOI] [PubMed] [Google Scholar]

Articles from Biophysical Journal are provided here courtesy of The Biophysical Society

RESOURCES