Skip to main content
Annals of Surgery logoLink to Annals of Surgery
. 1965 Sep;162(3):329–345. doi: 10.1097/00000658-196509000-00003

Heterologous liver perfusion in treatment of hepatic failure.

B Eiseman, D S Liem, F Raffucci
PMCID: PMC1476914  PMID: 5318668

Full text

PDF
329

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. COOK D. L., LAWLER C. A., GREEN D. M. Studies on the effect of hydrocholeretic agents on hepatic excretory mechanisms. J Pharmacol Exp Ther. 1954 Mar;110(3):293–299. [PubMed] [Google Scholar]
  2. EISEMAN B., BAKEWELL W., CLARK G. Studies in ammonia metabolism. I. Ammonia metabolism and glutamate therapy in hepatic coma. Am J Med. 1956 Jun;20(6):890–895. doi: 10.1016/0002-9343(56)90209-1. [DOI] [PubMed] [Google Scholar]
  3. EISEMAN B., KNIPE P., MCCOLL H. A., ORLOFF M. J. Isolated liver perfusion for reducing blood ammonia. Arch Surg. 1961 Sep;83:356–363. doi: 10.1001/archsurg.1961.01300150030004. [DOI] [PubMed] [Google Scholar]
  4. Eiseman B., Knipe P., Koh Y., Normell L., Spencer F. C. Factors Affecting Hepatic Vascular Resistance in the Perfused Liver. Ann Surg. 1963 Apr;157(4):532–547. doi: 10.1097/00000658-196304000-00008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Eschbach J. W., Jr, Hutchings R. H., Meston B., Burnell J. M., Scribner B. H. A technique for repetitive and long-term human cross circulation. Trans Am Soc Artif Intern Organs. 1964;10:280–284. [PubMed] [Google Scholar]
  6. HU A. S., CLINE A. L. THE REGULATION OF SOME SUGAR DEHYDROGENASES IN A PSEUDOMONAD. Biochim Biophys Acta. 1964 Nov 8;93:237–245. doi: 10.1016/0304-4165(64)90371-x. [DOI] [PubMed] [Google Scholar]
  7. JOYEUSE R., IVANISEVIC B., LONGMIRE W. P., Jr, MALONEY J. V., Jr THE TREATMENT OF EXPERIMENTAL HEPATIC COMA BY PARABIOTIC CROSS CIRCULATION. Surg Gynecol Obstet. 1963 Aug;117:129–138. [PubMed] [Google Scholar]
  8. LIEM D. S., WALTUCH T. L., EISEMAN B. FUNCTION OF THE EX-VIVO PIG LIVER PERFUSED WITH HUMAN BLOOD. Surg Forum. 1964;15:90–91. [PubMed] [Google Scholar]
  9. OTTO J. J., PENDER J. C., CLEARY J. H., SENSENIG D. M., WELCH C. S. The use of a donor liver in experimental animals with elevated blood ammonia. Surgery. 1958 Feb;43(2):301–309. [PubMed] [Google Scholar]
  10. SELIGSON D., HIRAHARA K. The measurement of ammonia in whole blood, erythrocytes, and plasma. J Lab Clin Med. 1957 Jun;49(6):962–974. [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins

RESOURCES