Skip to main content
. 2006 May 26;103(23):8680–8685. doi: 10.1073/pnas.0510191103

Table 1.

Statistics of superstall backward stepping

Force, pN Steps within a backward run*
First backward step after a forward step
Rate constant λ1, s−1 Rate constant λ2, s−1 Amplitude ratio Z2/Z1 n Rate constant, s−1 n
    3 11.9 ± 2.6 1.7 ± 0.7 1.04 395 1.6 ± 0.2 78
 5 17.4 ± 3.3 2.6 ± 1.4 0.64 675 2.6 ± 0.3 82
10 35.5 ± 5.6 3.8 + 5/−3.7 0.03 198 6.3 ± 2.4 20

*Data include experiments with 0, 0.25, and 1 μM ATP (displayed in Fig. 3D).

Data include experiments with 0.25 and 1 μM ATP. The rate constant is calculated as the inverse of the average dwell time.