Table 2.
GT | CT | CC | AT | |
---|---|---|---|---|
Rct (Ω) | ||||
MutS | (2.43 ± 0.51) × 104 | (3.06 ± 0.43) × 104 | (3.82 ± 0.68) × 104 | (3.78 ± 0.70) × 104 |
2 µM | (3.24 ± 0.23) × 104 | (3.78 ± 0.18) × 104 | (4.12 ± 0.27) × 104 | (3.87 ± 0.15) × 104 |
6 µM | (4.52 ± 0.31) × 104 | (4.34 ± 0.25) × 104 | (4.42 ± 0.29) × 104 | (3.22 ± 0.17) × 104 |
10 µM | (5.86 ± 0.36) × 104 | (4.85 ± 0.24) × 104 | (4.92 ± 0.25) × 104 | (3.98 ± 0.19) × 104 |
ΔRct (Ω) | ||||
2 µM | 8050 | 7190 | 3000 | 860 |
6 µM | 20 810 | 12 730 | 6000 | 1410 |
10 µM | 34 200 | 17 870 | 11 020 | 2030 |
%(ΔRct) | ||||
2 µM | 33 | 23 | 8 | 2 |
6 µM | 85 | 41 | 16 | 4 |
10 µM | 140 | 58 | 21 | 6 |
Detection limitb (µM) 0.044 | 0.13 | 0.31 | 1.56 |
aThe values of Rct are mean ± SD of three repeated experiments.
bDetection limit , (, mean of blank; Sbl, standard deviation of blank; k, detection limit constant, blank contains only the MutS solution).