Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 2003 Mar;69(3):1844–1846. doi: 10.1128/AEM.69.3.1844-1846.2003

Comparison of Methods for DNA Isolation from Food Samples for Detection of Shiga Toxin-Producing Escherichia coli by Real-Time PCR

Loree C Heller 1,*, Carisa R Davis 2, K Kealy Peak 2, David Wingfield 3, Andrew C Cannons 2, Philip T Amuso 2,3, Jacqueline Cattani 2
PMCID: PMC150052  PMID: 12620880

Abstract

In this study, food samples were intentionally contaminated with Escherichia coli O157:H7, and then DNA was isolated by using four commercial kits. The isolated DNA samples were compared by using real-time PCR detection of the Shiga toxin genes. The four kits tested worked similarly.


Enteric pathogens are classic potential agents of bioterrorism. For example, Salmonella enterica serovar Typhimurium was used to contaminate salad bars in an attempt to affect the outcome of a local election (7). In another instance, Shigella dysenteriae type 2 obtained from a laboratory was used by a medical technologist as an agent to sicken coworkers (3). Foods that are uncooked or undercooked after manufacture make feasible targets for intentional contamination. Conventional microbiological techniques for the detection of bacterial pathogens in food, including isolation on selective media and biochemical identification of the bacteria, are time-consuming and laborious. More-rapid alternatives, including the detection of pathogen DNA by real-time PCR, are available (1, 8). In this study, four commercial kits for isolation of DNA from food samples were compared by real-time PCR detection.

Bread slices, ground beef, commercially bagged salad greens, and salad dressing were purchased at local grocery stores. To confirm that none of these products already contained Shiga toxin-producing Escherichia coli, each product was tested for total coliform bacteria by using the Food and Drug Administration Bacteriological Analytic Manual Online (www.cfsan.fda.gov/∼ebam/bam-toc.html) protocol. All enriched gram-negative bacilli were identified by classical microbiological techniques (5). Biochemical differentiations were made with the API 20E identification system for Enterobacteriaceae and other gram-negative rods (bioMerieux Vitek, Inc., Hazelwood, Mo.) with supplemental conventional biochemical tests as required. While both bread and salad dressing samples were negative for all coliforms, a variety of gram-negative organisms were isolated from the ground beef and salad greens after enrichment (Table 1). The E. coli strains isolated from the ground beef samples were tested per the manufacturer's instructions and were not identified as O157 or O157:H7 (SAS E. coli O157:H7 and E. coli O157 test; SA Scientific, San Antonio, Tex.).

TABLE 1.

Coliform enrichment of foods before intentional contamination

Food Sample no. Total coliforms/g Fecal coliforms/g Organism(s) isolated
Bread slices 1 0 0 None
Ground beef 1 3.1 3.1 Escherichia coli
2 24 0.36 Escherichia coli, Citrobacter braakii, Acinetobacter calcoaceticus, Hafnia alvei
Salad greens 1 21 0 Enterobacter cloacae, Pseudomonas putida, Rahnella aquatilis
2 9.3 0 Klebsiella planticola, Pseudomonas putida, Pseudomonas fluorescens
Salad dressing 1 0 0 None

Ten grams of each food product was spiked with E. coli O157:H7 (ATCC 700927) cells from Trypticase soy broth (TSB) and incubated for 16 h at 35°C. Assuming 100% efficiency in DNA isolation, an approximate amount of 1,000 CFU was included in each final PCR. Samples were diluted 1:10 (wt/vol) with TSB and homogenized for 1 min. One milliliter of homogenate was removed, and the DNA was isolated with four commercial kits (Table 2). Prepman Ultra (Applied Biosystems, Foster City, Calif.) and Bugs'n Beads (GenPoint, Oslo, Norway) were designed to extract the DNA from a wide variety of gram-positive and gram-negative bacteria in foods. The NucleoSpin food kit (Clontech, Palo Alto, Calif.) and the Wizard magnetic DNA purification system for food (Promega Madison, Wis.) were designed for detection of genetically modified organisms but were tested here for the additional isolation of bacterial genomic DNA. After DNA isolation per each manufacturer's instructions, sterile molecular-grade water was added to each DNA sample as necessary to achieve a final volume of 200 μl. Since in all kits except Bugs'n Beads the isolated DNA may contain food as well as bacterial genomic DNA, it was not possible to directly quantify the DNA yield.

TABLE 2.

Commercial kits used for DNA isolation from foods

Kit Method Ease of use
Prepman Ultra Proprietary solution Very simple, minimum manipulation of sample
Bugs'n Beads Magnetic beads Simple, centrifuge not absolutely necessary
NucleoSpin food kit Spin columns Considerable hands-on time
Wizard magnetic DNA purification system for food Magnetic beads Considerable hands-on time, centrifuge not absolutely necessary

To determine which DNA isolation method most effectively produced PCR-quality DNA, the DNA was subjected to TaqMan PCR using the primers and probes targeting the stx1 and stx2 genes (Table 3). Each 50-μl reaction mixture contained 1× TaqMan master mix, 45 pmol of each primer, 12.5 pmol of probe, and 5 μl of DNA. Thermal cycling and detection were performed by employing an ABI Prism 7700 sequence detection system using the associated version 1.7a application software as described by the manufacturer and by employing default parameters. To compare detection limits between the different kit brands, the threshold cycle (Cτ) value for each sample was divided by the log of the CFU used to spike the sample (Table 4). If a reaction reached cycle 40 without a significant increase in fluorescence, this reaction contained no DNA and was considered to be negative.

TABLE 3.

Oligonucleotides for detection of stx1 and stx2 genesa

Gene Primer or probe Sequenceb
stx1c Forward primer 5′-TGTCACATATAAATTATTTCGTTC AACAA-3′
Reverse primer 5′-GCAGTTGATGTCAGAGGGATAGA TC-3′
TaqMan probe 5′-6-FAM-AAGCCGTAGATTATTAAAC CGCCCTTCCTCT-BHQ1-3′
stx2d Forward primer 5′-CAACGTGTCGCAGCGCT-3′
Reverse primer 5′-AACGCCAGATATGATGAAACCA-3′
TaqMan probe 5′-6-FAM-TCCGGAATGCAAATCAGT CGTCACTCA-BHQ1-3′
a

All oligonucleotides were purchased from IDT DNA (Coralville, Iowa).

b

6-FAM, 6-carboxyfluorescein; BHQ, Black Hole Quencher.

c

Corresponding to bp 2996678 to 2996764 of E. coli O157:H7 EDL933 (GenBank accession number NC_002655).

d

Corresponding to bp 1352707 to 1352780 of E. coli O157:H7 EDL933 (GenBank accession number NC_002655).

TABLE 4.

Mean Cτ/log CFU values and standard errors of three independent experiments each using Taqman PCR detection after intentional contamination of foods with E. coli O157:H7

Food Target gene Cτ/log CFU (mean ± SE) determined by:
Prepman Ultra Bugs'n Beads Nucleospin food kit Wizard magnetic DNA purifica- tion system for food
TSB stx1 10.2 ± 0.4 10.7 ± 0.4 9.8 ± 0.4 10.1 ± 0.3
stx2 10.4 ± 0.3 11.1 ± 0.4 10.3 ± 0.3 10.7 ± 0.3
Bread stx1 9.8 ± 0.2 11.0 ± 0.2 10.1 ± 0.5 9.8 ± 0.3
stx2 9.4 ± 0.3 10.9 ± 0.4 9.8 ± 0.4 9.7 ± 0.4
Ground beef stx1 10.3 ± 0.3 12.2 ± 0.2 11.1 ± 0.5 9.7 ± 0.3
stx2 10.3 ± 0.3 12.5 ± 0.4 11.6 ± 0.5 9.7 ± 0.2
Salad greens stx1 10.0 ± 0.1 10.9 ± 0.2 10.0 ± 0.0 10.1 ± 0.2
stx2 10.0 ± 0.2 10.9 ± 0.0 10.0 ± 0.2 10.4 ± 0.2
Salad dressing stx1 10.0 ± 0.3 10.3 ± 0.4 10.0 ± 0.8 9.4 ± 0.3
stx2 10.0 ± 0.3 10.3 ± 0.5 9.5 ± 0.3 10.1 ± 0.6

For both primer sets, the Cτ/log CFU values were grouped by food type. These values were found to be normal by using the Shapiro-Wilk test, and no significant effect due to the experiments being done on different days was found by a one-way analysis of variance. To test for differences between the four kits, a one-way analysis of variance was used, followed by a posteriori comparisons. In addition, to ensure that the experiment-wise error rate did not exceed 5%, we conducted the sequential Bonferroni procedure in which the alpha level is divided by the number of tests (in this case, five) and the resulting value is used to determine significance (6). Statistical analysis was conducted using the SAS system for Windows version 8.0 (SAS Institute, Cary, N.C.).

Overall significant differences were found with the results for both primer and probe sets for ground beef and salad greens, but only those for ground beef had significant contrasts. For both the primer and probe sets, the only two kits whose results were significantly different from each other were Bugs'n Beads and the Wizard magnetic DNA purification system for food. In this case, Bugs'n Beads was less sensitive.

Since Prepman Ultra was the easiest method to perform and its results did not differ significantly from the results of the other kits, this isolation method was further characterized (Fig. 1). Foods were intentionally contaminated with 10-fold dilutions of E. coli O157:H7. Since cell viability does not affect detection of DNA by PCR (2, 4), in this experiment stocks frozen at −80°C in TSB containing 15% glycerol were used. DNA was extracted as described above, PCR was performed, and a linear regression of Cτ values on log CFU per PCR was used in order to determine the detection limit. Although the TSB control had significantly lower Cτ values at the same number of CFU, no significant difference was observed between the detection limits for the foods and the TSB control (Fig. 1). The overall mean detection limit, with a 5-μl aliquot of the 200 μl of DNA isolated, was 13.35 CFU/PCR, which corresponded to 5,340 CFU per g of food. This value represents the practical detection limit of this method, although this limit would be theoretically lower if the entire DNA solution was used, for example, by concentrating the DNA before PCR.

FIG. 1.

FIG. 1.

Real-time PCR detection of E. coli O157:H7 from DNA isolated with the Prepman Ultra kit from various intentionally contaminated foods. Cτ values are plotted against the log10 CFU. (A) Detection of the stx1 gene. ⧫, salad greens (r2 = 0.997); □, ground beef (r2 = 1.00); ▵, salad dressing (r2 = 0.97); -, bread (r2 = 0.98); •, TSB (r2 = 0.999). (B) Detection of the stx2 gene. ⧫, salad greens (r2 = 0.996); □, ground beef (r2 = 0.99); ▵, salad dressing (r2 = 0.97); -, bread (r2 = 0.99); •, TSB (r2 = 0.99). The means and standard errors of the results of three independent experiments are indicated.

The development of alternative assays for detection of pathogenic organisms commonly associated with food-borne diseases will allow early detection of food-related bioterrorism events and will also strengthen surveillance to provide timely detection of natural epidemics. Each kit tested efficiently isolated DNA from the four tested foods. Based simply on ease of use, the Prepman Ultra method was preferred.

Acknowledgments

This work was supported by Department of Defense contract number DAAD13-01-C-0043.

REFERENCES

  • 1.Jordan, J. A. 2000. Real-time detection of PCR products and microbiology. New technologies for life sciences: a trends guide. 6:61-66.
  • 2.Josephson, K. L., C. P. Gerba, and I. L. Pepper. 1993. Polymerase chain reaction detection of nonviable bacterial pathogens. Appl. Environ. Microbiol. 59:3513-3515. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Kolavic, S. A., A. Kimura, S. L. Simons, L. Slutsker, S. Barth, and C. E. Haley. 1997. An outbreak of Shigella dysenteriae type 2 among laboratory workers due to intentional food contamination. JAMA 278:396-398. [PubMed] [Google Scholar]
  • 4.Masters, C. I., J. A. Shallcross, and B. M. Mackey. 1994. Effect of stress treatments on the detection of Listeria monocytogenes and enterotoxigenic Escherichia coli by the polymerase chain reaction. J. Appl. Bacteriol. 77:73-79. [DOI] [PubMed] [Google Scholar]
  • 5.Murray, P. R., E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.). 1999. Manual of clinical microbiology, 7th ed. ASM Press, Washington, D.C.
  • 6.Rice, W. R. 1989. Analyzing tables of statistical tests. Evolution 43:223-225. [DOI] [PubMed] [Google Scholar]
  • 7.Torok, T. J., R. V. Tauxe, R. P. Wise, J. R. Livengood, R. Sokolow, S. Mauvais, K. A. Birkness, M. R. Skeels, J. M. Horan, and L. R. Foster. 1997. A large community outbreak of salmonellosis caused by intentional contamination of restaurant salad bars. JAMA 278:389-395. [DOI] [PubMed] [Google Scholar]
  • 8.Wittwer, C. T., M. G. Herrmann, A. A. Moss, and R. P. Rasmussen. 1997. Continuous fluorescence monitoring of rapid cycle DNA amplification. Biotechniques 22:130-131, 134-138. [DOI] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES