TABLE 1.
Transition times estimated for PcrA translocation in two limiting scenarios
| Time | Physical correspondence | Weak coupling | Strong coupling |
|---|---|---|---|
| 1/r1 | 1A moving forward | 19 ms | 0.3 ms |
| 1/s2 | 2A moving backward | 3 × 106 s | 4 × 104 s |
| 1/r2 | 2A moving forward | 0.8 ms | 0.03 μs |
| 1/s1 | 1A moving backward | 6 × 102 s | 14 ms |
| 1/ωI | No domain movement | 100 ns (assumed) | 15.4 ms |
| 1/ωII | No domain movement | 100 ns (assumed) | 4.6 ms |
The corresponding domain movements (or lack of movement) of the associated transitions are stated.