TABLE 2.

Comparison of autolysis detection methods

Detection method Potential of mixed-population analyses Sensitivity to autolysis Considerations
CFU measurement Low Not sensitive (5) Cells may form aggregates; cells may be nonculturable but still not lysed (5)
A600 measurement Not possible Medium Influenced by extracellular material
Electron microscopy (26) Low Medium No quantification can be made
BacLight (5) Not possible Medium Quantification is difficult (26)
Intracellular metabolic enzyme, e.g., LDH (9, 30) Mediuma High Sensitive to enzyme activity
Immunological (10, 46) Medium High Difficulty in identifying species-specific immunological markers and in obtaining quantitative results
DNA array High High Sensitive to DNA degradation
a

Different isomers of LDH (10) or requirements for a cofactor for LDH activation (14) make differentiation achievable.