Skip to main content
. 2006 Sep 29;6:83. doi: 10.1186/1471-2180-6-83

Table 1.

Comparison of the BacLite Rapid MRSA test results with those obtained by the reference method

BacLite MRSA positive BacLite MRSA negative Total
Reference method: MSAO culture and confirmatory tests Positive 142 15 157
Negative 53 1172 1225