TABLE 1.
Compound | GC-MS
|
Retention time in HPLC (min)c | |
---|---|---|---|
Retention time (min)a | Relative %b | ||
1 | 41.1d | <0.1 | 8.2 |
2 | 24.6e | 0.8 | 6.8 |
3 | 20.1e | 36.7 | 20.5 |
4 | 19.9e | 2.9 | 33.0 |
5 | 23.0e | 10.3 | 8.7 |
6 | 22.4e | 1.5 | 12.9 |
7 | 18.8e | 2.6 | 12.5 |
8 | 18.1e | 15.6 | 15.8 |
9 | 20.7e | 17.2 | 17.2 |
10 | 21.4e | 3.5 | 17.9 |
11 | 17.6e | 9.0 | 16.7 |
Sample solution 1 mg/ml; injection volume, 1 μl; split ratio, 1/5; Perkin-Elmer PE-1 column (30 m by 0.32 mm [inside diameter]); and He (2 ml/min) as the carrier gas.
The total amount of compounds 1 to 11 was defined as 100%.
Determined by using a Eurospher 100-C18 column (5 μm; 250 by 8 mm) and a solvent system consisting of H2O, methanol, and CH2Cl2 in a gradient from 15 to 0% H2O in 10 min, from 85 to 40% methanol in 30 min, and 0 to 60% CH2Cl2 in 30 min (flow rate, 2 ml/min).
Determined by using GC-MS method 2.
Determined by using GC-MS method 1.