Table 2.
Signal Averaging of Telemetry ECG Data
WT (n = 4) | 8/8 (n = 7) | |
---|---|---|
R-Amp (mv) | 0.452 ± 0.145 | 0.197 ± 0.021* |
QRS (ms) | 16.3 ± 0.5 | 16.1 ± 1.1 |
RR (ms) | 103.3 ± 5.1 | 154.7 ± 63.4 |
QT (ms) | 85.5 ± 4.4 | 78.3 ± 17.6 |
RT (ms) | 54.3 ± 3.5 | 53.0 ± 14.2 |
HR (bpm) | 582.9 ± 29.3 | 441.9 ± 168.2 |
Telemetry recordings of ECG data from 4 wild-type (WT) and 7 ACE 8/8 mice were averaged. R-Amp represents R wave amplitude. QRS, RR, QT, and RT represent the intervals of respective waves. HR represents heart rate.
p < 0.01. All data are means ± SEM.