Skip to main content
. 2003 May 7;100(11):6878–6883. doi: 10.1073/pnas.1131995100

Table 1. Period and phase differences between CAB2::LUC and CAT3::LUC in continuous conditions after entrainment to different LD and temperature cycles.

Condition Reporter gene Period ± SEM, hr P*
LL hot/cold CAT3::LUC 25.15 ± 0.18 0.8240
CAB2::LUC 25.21 ± 0.20
LD continuous hot CAT3::LUC 24.56 ± 0.28 <0.0001
CAB2::LUC 26.29 ± 0.31
LD hot/cold CAT3::LUC 25.19 ± 0.18 <0.0001
CAB2::LUC 26.41 ± 0.20
LD cold/hot CAT3::LUC 24.18 ± 0.21 <0.0001
CAB2::LUC 26.65 ± 0.27
*

As determined by Student's t test.