TABLE 2.
Filter | No. of oocysts counted (FITC labeled/DAPI labeleda) | Sensitivityb as determined by:
|
|
---|---|---|---|
Direct PCR | Two-step nested PCR | ||
F filtersc | |||
F1 | 11/6 | Negative | ND |
F2 | 6/5 | 1+ | 4+ |
F3 | 4/0 | 1+ | 4+ |
F4 | 8/7 | Negative | 4+ |
F5 | 7/4 | Negative | 4+ |
F6 | 8/4 | Negative | 3+ |
F7 | 7/5 | Negative | 4+ |
F8 | 4/2 | Negative | 2+ |
F9 | 6/5 | Negative | 1+ |
F10 | 12/10 | Negative | 3+ |
F11 | 10/7 | 1+ | 4+ |
F12e | 9/2 | Negative | 4+ |
FC filtersd | |||
FC1 | 5/2 | Negative | 3+ |
FC2 | 9/2 | Negative | 4+ |
FC3 | 9/3 | Negative | 4+ |
FC4 | 4/1 | Negative | 4+ |
FC5 | 15/9 | Negative | 3+ |
FC6 | 2/1 | 1+ | 3+ |
FC7 | 13/10 | 1+ | 4+ |
FC8 | 7/2 | Negative | 3+ |
FC9 | 12/5 | Negative | 3+ |
DAPI labelling refers to oocysts containing one to four nuclei.
Negative, no PCR product detected on gel; 4+, PCR product yielding a strong band; 3+ and 2+, PCR product yielding medium-strength bands; 1+, PCR product yielding a weak band on the gel; ND, not done.
F filters, filters through which seeded mineral water A was passed.
FC filters, filter controls (filters onto which a known number of oocysts were deposited [see text]).
Filtration of 1 liter of RO water.