Skip to main content
. 2006 Nov-Dec;13(6):691–695. doi: 10.1197/jamia.M2078

Table 1.

Table 1. Agreement between Automatic and Manual Concept Extraction

Measure Overall Agreement Sensitivity Specificity Positive Predictive Value
Numeric value of documented blood pressure 93.0% (± 2.9%) 90.6% (± 3.3%) 96.1% (± 2.2%) N/A
Documentation of elevated blood pressure (Boolean) 98.3% (± 1.5%) 98.2% (± 1.5%) 98.4% (± 1.4%) 93.2% (± 6.4%)
Documentation of anti-hypertensive treatment intensification (Boolean) 92.0% (± 3.1%) 83.8% (± 4.2%) 95.0% (± 2.5%) 85.9% (± 7.7%)

95% confidence interval is indicated in parentheses.