Skip to main content
. 2004 Mar 5;557(Pt 3):705–717. doi: 10.1113/jphysiol.2003.058578

Table 1.

Effects of [K+]o on steady-state activation properties and deactivation kinetics measured with the two-electrode voltage clamp techinque

[K+]o (mm) k (mV) V½ (mV) τdeact(ms)
2.0 (n = 5) 19.7 ± 0.7 − 31.7 ± 2.1 21.7 ± 0.8
5.0 (n = 5) 20.7 ± 0.7 − 32.1 ± 2.2 22.1 ± 0.7
10.0 (n = 5) 21.7 ± 1.2 − 30.2 ± 2.4 20.5 ± 0.6
50.0 (n = 5) 18.2 ± 0.7* − 34.7 ± 1.5** 30.1 ± 2.4***

Data are expressed as means ±s.e.m. P statistics are based on comparison of data at 10 and 50 mm [K+]o.

*

P < 0.03

**

P < 0.02

***

P < 0.01. τdeact was measured at −45 mV.