Skip to main content
. 1999 Oct;83(10):1106–1111. doi: 10.1136/bjo.83.10.1106

Figure 1  .

Figure 1  

Stress-strain curves for cornea and sclera. Each line represents the value from 12 corneal or scleral samples (A). Stress-strain curve for the simulation model is derived from experimental values and the data of past reports. Penetrating ocular injury is assumed to occur at a strain of 18.0% in cornea and 6.8% in sclera (B).