Skip to main content
. 2003 Jan;89(1):84–90. doi: 10.1136/heart.89.1.84

Table 1.

Patient and target lesion before coronary interventions

Direct stenting (n=30) Predilation stenting (n=30) p Value
Vessel treated
    LAD 13 (43%) 15 (50%) NS
    LCx 9 (30%) 7 (23%) NS
    RCA 8 (27%) 8 (27%) NS
IVUS mean diameter reference (mm) 3.05 (0.5) 2.82 (0.4) 0.08
Plaque eccentricity ratio 3.62 (2.3) 3.64 (3.2) NS
Plaque composition
    Soft 17 (57%) 12 (41%) NS
    Heterogeneous 8 (27%) 13 (43%) NS
    Dense 5 (16%) 5 (16%) NS
Mean remodelling ratio −5.2 (25) 0.8 (35) NS
Positive remodelling (n) 9 12 NS
Negative remodelling (n) 21 18 0.02
Number of balloon inflations 1.9 (0.7) 3.9 (1.1) <0.001
Mean diameter of stent used (mm) 3.48 (0.4) 3.23 (0.4) 0.02
Maximum BIP (atm) 15.13 (3.18) 12.4 (2.35) 0.001
Stent/artery ratio 1.24 (0.13) 1.23 (0.17) NS

Values are mean (SD) unless stated.

BIP, balloon inflation pressure; IVUS, intravascular ultrasound; LAD, left anterior descending coronary artery; LCx, left circumflex coronary artery; RCA, right coronary artery.