Skip to main content
. 2005 Feb;91(2):203–206. doi: 10.1136/hrt.2003.027797

Table 2.

 Angiographic and pressure data before and after stent implantation

Before After p Value
MLD (mm) 0.85 (0.43) 3.01 (0.69) <0.0001*
Mean reference diameter (mm) 2.88 (0.69) 3.11 (0.71) <0.0001*
DS (%) 70 (14) −2 (15) <0.0001*
FFR 0.65 (0.15) 0.94 (0.06) <0.0001†
Lesion length (mm) 11 (6)
Stent length (mm) (range) 18 (9) (8 to 54)
Number of stents 1.29 (0.57)

Data are mean (SD).

*t Test for paired samples; †Wilcoxon signed rank test.

DS, diameter stenosis, FFR, fractional flow reserve; MLD, minimum lumen diameter.