Table 1.

 Comparison of the results of FT for first and recurrent episodes of PVT

Extent of response Haemodynamic Clinical
First episode Recurrent episodes p Value First episode Recurrent episodes p Value
Complete 36 (73.5) 15 (57.7) 0.16 33 (67.3) 13 (50) 0.14
    Partial 7 (14.3) 5 (19.2) 0.82 10 (20.4) 7 (26.9) 0.72
    Failure 6 (12.2) 6 (23.1) 0.37 6 (12.2) 6 (23.1) 0.37
Clinical failure
Death 3 (6.1) 1 (3.8) 0.57
Stroke 3 (6.1) 6 (23.1) 0.04
Major bleed 0 1 (3.8)
Major complications and death 6 (12.2) 8 (30.7) 0.05
Minor bleed 2 (4.1) 1 (3.8) 0.725