Skip to main content
. 2007 Jan 15;2:6. doi: 10.1186/1748-717X-2-6

Table 3.

Dose-volume histogram and treatment volumes constraints:

Structure Maximum Volume/Maximum Total Dose
Bladder ≤ 55%/≥ 47 Gy ≤ 30%/≥ 70 Gy Maximum dose: 82 Gy
Rectum ≤ 55%/≥ 47 Gy ≤ 40%/≥ 65 Gy ≤ 25%/≥ 70 Gy
≤ 10%/≥ 75 Gy Maximum dose: 82 Gy
Femoral head Maximum dose: 50 Gy
PTV Maximum dose ≤ 20% of prescription dose to PTV
Minimum dose of 70 Gy if prescription dose of 72 Gy to PTV
Minimum dose of 72 Gy if prescription dose of 74 Gy to PTV
Minimum dose of 74 Gy if prescription dose of 76 Gy to PTV
Minimum dose of 76 Gy if prescription dose of 78 Gy to PTV
PTV's coverage to a minimum of 95% of the entire volume

PTV: planning target volume