Skip to main content
. 2004 Dec 8;65(8):1084–1087. doi: 10.1136/ard.2005.045781

Table 2 Synovial fluid analysis from the knee with the reciprocating and conventional syringes.

White blood Neutrophils (%) Monocytes (%) Lymphocytes (%) Red blood Volume (ml) No of knee fluid samples
cells/mm3 cells/mm3
Conventional syringe 11 439 (9786) 60.6 (35.5) 27.8 (25.4) 11.7 (10.7) 49 222 (79 513) 8.89 (2.47) 9
Reciprocating syringe 16 950 (14 089) 59.7 (25.8) 29.7 (27.8) 8.29 (5.54) 14 832 (14 906) 13.26 (6.47) 9
Significance p = 0.20 p = 0.91 p = 0.65 p = 0.49 p = 0.24 p = 0.06

Values are mean (SD).