Skip to main content
. 2006 Dec;104:493–516.

TABLE 11.

A COMPARISON OF 3½ -YEAR CRYO-ROP STUDY HOTV RECOGNITION ACUITY OUTCOME DATA WITH 3½ -YEAR HOTV RECOGNITION ACUITY OUTCOMES OF THIS EXTREMELY LOW-BIRTH-WEIGHT (ELBW) COHORT

TREATED EYES (n=203) 148 EYES TESTED CONTROL EYES (n=203) 146 EYES TESTED COMBINED EYES (n=406) 294 EYES TESTED ELBW COHORT (n=64)
Favorable 79 (53.4%) 62 (42.5%) 141 (48.0%) 52 (81.3%)
Normal 43 (29.1%) 42 (28.8%) 85 (28.9%) 38 (59.4%)
Below normal 36 (24.3%) 20 (13.7%) 56 (19.1%) 14 (21.9%)
Unfavorable 69 (46.6%) 84 (57.5%) 153 (52.0%) 12 (18.8%)
Poor vision 14 (9.5%) 6 (4.1%) 20 (6.8%) 1 (1.5%)
Blind/low vision 55 (37.2%) 78 (53.4%) 133 (45.2%) 11 (17.2%)

CRYO-ROP = Cryotherapy for Retinopathy of Prematurity.