Skip to main content
. 2006 Dec;104:143–148.

TABLE 2.

MULTIVARIABLE MODEL OF ASSOCIATION OF INTRAOCULAR PRESSURE (IOP) AND VERTICAL CUP-TO-DISC RATIO, RIGHT EYES AT BASELINE

AGE/GENDER ADJUSTED AGE/GENDER/REFRACTION ADJUSTED
VARIABLE ESTIMATE* SE PVALUE ESTIMATE* SE PVALUE
Intercept 0.3170 0.0096 <.001 0.3193 0.0098 <.001
Age, 43–54 yr 0 0
 55–64 yr −0.0003 0.0050 .95 −0.0058 0.0051 .26
 65–74 yr 0.0049 0.0051 .34 −0.0015 0.0054 .79
 75+ yr 0.0194 0.0062 .002 0.0076 0.0068 .27
Sex (men) 0.0054 0.0039 .17 0.0057 0.0039 .15
Refraction, per diopter 0.0042 0.0009 <.001
IOP, per 1 mm Hg 0.0024 0.0006 <.001 0.0025 0.0006 <.001

SE = standard error of estimate.

*

Estimate is the amount of change in cup-to-disc ratio for every unit of change in the variable. For the intercept, this represents the cup-to-disc ratio value setting all other variables equal to zero.