Table 3.
Univariate and multivariate logistic regression analysis and areas under the receiver operating characteristic curve (ROC-AUC) of the ovarian reserve tests for the prediction of 'poor' response in IVF.
Variable | N | P | ROC AUC |
Univariate analysis | |||
Age (y) | 110 | 0.033 | 0.63 |
bFSH (IU/l) | 110 | < 0.0001 | 0.83 |
bFSH + sFSH in the CCCT (IU/l) | 56 | < 0.0001 | 0.88 |
E2-increment in the EFORT (pmol/l) | 54 | 0.006 | 0.75 |
Inh.B-increment in the EFORT (ng/l) | 54 | < 0.0001 | 0.86 |
Total ovarian volume (ml) | 110 | < 0.0001 | 0.77 |
Total antral follicle count | 110 | < 0.0001 | 0.83 |
Multivariate analysis CCCT GROUP |
|||
bFSH + sFSH in the CCCT (IU/l)) | 56 | < 0.0001 | 0.88 |
Multivariate analysis EFORT GROUP |
|||
Total antral follicle count | 54 | 0.003 | 0.88 |