Table 1 Axial length at surgery, refractive target and postoperative refraction.
Patient | Eye | Axial length (mm) | Target post‐op refraction (D) | Implant power and type | Measured first post‐op refraction | Refraction at 3 years or latest (L) |
---|---|---|---|---|---|---|
1 | Left | 19.78 | 6.11 | 24 D Pharmacia | 4.00 | −1.78 |
Right | 19.68 | 6.00 | 24 D Pharmacia | 4.50 | 0.04 | |
2 | Right | 17.79 | 8.88 | 28 D Pharmacia | 8.00 | 4.35 |
Left | 17.8 | 9.53 | 27 D Pharmacia | 10.00 | 2.35 | |
3 | Left | 18.62 | 5.90 | 28 D Acrysof | 8.75 | 0.25 |
Right | 20.76 | 4.60 | 24 D Acrysof | 5.50 | 1.56 | |
4 | Right | 18.6 | 7.30 | 30 D Acrysof | 5.00 | 4.67 |
Left | 18.81 | 6.28 | 30 D Acrysof | 4.25 | 5.85 | |
5 | Right | 17.02 | 9.56 | 30 D Acrysof | 8.25 | 6 (L) |
Left | 16.84 | 9.92 | 30 D Acrysof | 9.50 | 7 (L) | |
6 | Right | 17.22 | 6.88 | 30 D Acrysof | 8.25 | −0.63 (L) |
Left | 18.66 | 6.41 | 30 D Acrysof | 8.00 | −0.13 (L) | |
7 | Right | 18.84 | 6.35 | 29 D Acrysof | 3.38 | −2 (L) |
No op | — | — | — | — | — | |
8 | Left | 21.98 | 1.84 | 23 D Acrysof | 2.00 | −1 (L) |
No op |
op, operation; Pharmacia intraocular lens (IOLs) were 811C heparin‐coated; Acrysof IOLs were MA60; median first postoperative (post‐op) refraction at 14 days post‐op (range 1–60 days); median first postop refraction = 6.75 D sphere (range 2–10); median difference (target post‐op refraction—measured first post‐op refraction) = 0.65 D sphere; range (−2.85 to 2.97 D sphere); median refraction at 3 years (estimated from graphs, n = 8 eyes of 4 patients) post‐op = 1.96 D sphere.