Skip to main content
. 2006 Oct 25;93(4):506–509. doi: 10.1136/hrt.2006.094169

Table 2 Clinical events after surgery.

Preoperative QRS (ms)
Missing preoperative QRS (n = 16) <120 (n = 18) 120–150 (n = 19) 150–180 (n = 30) ⩾180 (n = 16)
Composite end point ventricular arrhythmia (%) 0 6 5 7 25
Sudden cardiac death (%) 0 0 0 3 0
(Non) sustained VT/appropriate ICD discharge (%) 0 6 5 3 25†
Mean (SD) duration to QRS⩾180 ms (years) NA 68 (4.5) 42 (4.4) 23 (4.3)* 2 (2)*†
Patients reaching >180 ms after surgery (%) 6 0 0 13 56†
ICD implantation after surgery (%) 0 0 0 3 19
Homograft explantation after surgery (%) 19 11 5 7 6

ICD, implantable cardioverter‐defibrillator; VT, ventricular tachycardia.

*Calculated from mixed linear regression analysis (fig 2).

†Significant difference between patients with pre‐operative QRS 150–180 (p<0.05).