Skip to main content
. 2002 Nov;54(5):463–471. doi: 10.1046/j.1365-2125.2002.01684.x

Table 2.

Optimal sampling strategies for the 1 h infusion.

Strategy Number of samples Sampling times after start of infusion
1 2 1 h 1.5 h
2 3 1 h 1.5 h 7 h
3 3 1 h 1.5 h 25 h
4 3 1 h 1.5 h 97 h
5 4 1 h 1.5 h 7 h 25 h
6 4 1 h 1.5 h 7 h 97 h
7 4 1 h 1.5 h 25 h 97 h
8 5 1 h 1.5 h 7 h 25 h 97 h