Skip to main content
. 2005 May;59(5):524–535. doi: 10.1111/j.1365-2125.2005.02368.x

Table 1.

Summary of analytical methodology performance for morphine, morphine 3- and 6-glucuronides (M3G, M6G, respectively), oxycodone and their N-demethylated metabolites, normorphine and noroxycodone, in plasma

Drug Mor Nmor M3G M6G NM3G IS-Hmor Oxy Noxy
Mrm signal 286/201 272/209 462/286 462/286 447/272 286/185 316/299 302/277
Recovery (%) 74 ± 7 68 ± 4 58 ± 4 40 ± 10 30 ± 4 37 ± 4 53 ± 3 51 ± 1
Calibration range plasma concentration (mg l−1) 0.078–5 0.039–2.5 0.156–10 0.039–2.5 0.039–2.5 0.078–5 0.078–2.5
LOQ (pg on column) 156 78 313 78 78 156 156