Skip to main content
. 2004;24:72–75.

TABLE 3. Mean Difference from Baseline for Each Material, Each Location, All Subjects at 5 min.

The mean differences and standard deviations of plantar surface temperature 5 minutes after walking for each material and location. Positive values indicate increased temperatures in degrees Fahrenheit. Materials tested included Bocklite (BOC), Pe-Lite (PEL), Plastazote (PLA), Poron (POR), Nylon-covered Poron (NPOR), Ortholite EVA (EVA), and a tri-laminate of Ortholite/Poron/Ortholite (TRI).

Bicep Hallux 1st Met 5th Met Heel
Mean (SD) p-val Mean (SD) p-val Mean (SD) p-val Mean (SD) p-val Mean (SD) p-val
TRI -0.85 (1.27) 0.2620 8.59 (8.00) 0.0180 6.74 (5.65) 0.0080 7.22 (6.16) 0.0100 6.00 (5.94) 0.0270
BOC -1.18 (1.48) 0.1120 6.09 (7.33) 0.0890 5.08 (4.45) 0.0100 4.65 (5.09) 0.0520 4.55 (5.17) 0.0640
NPOR -1.36 (1.46) 0.0460 7.63 (6.26) 0.0070 7.50 (4.74) 0.0008 7.50 (4.46) 0.0005 7.86 (4.96) 0.0008
POR 0.41 (5.44) 1.0000 11.02 (6.63) 0.0005 8.50 (4.05) 0.0000 8.72 (4.40) 0.0000 7.82 (6.16) 0.0050
PEL -1.38 (1.14) 0.0070 7.75 (9.64) 0.1070 5.99 (7.20) 0.0900 6.48 (8.14) 0.1130 5.88 (6.90) 0.0770
PLA -1.08 (1.17) 0.0460 7.53 (8.47) 0.0600 7.40 (6.20) 0.0080 8.62 (7.67) 0.0130 7.52 (5.92) 0.0050
EVA 0.22 (5.14) 1.0000 10.04 (7.13) 0.0020 9.02 (5.19) 0.0003 8.55 (5.48) 0.0009 7.52 (5.72) 0.0040
SHOE -0.42 (1.06) 1.0000 11.74 (7.64) 0.0010 7.83 (6.56) 0.0080 7.86 (7.42) 0.0190 6.85 (6.47) 0.0200