Skip to main content
. 2000 Dec 5;97(26):14278–14282. doi: 10.1073/pnas.260504897

Table 1.

Reconstitution of three components from three basis spectra

Spectra B0 (constant) B1 [k1 = 0.1322 ± 0.0010 (sec−1)] B2 [k2 = 0.891 ± 0.020 (sec−1)]
V1 −0.070888  ± 6.7 × 10−6
V2 0.04237  ± 0.00020 −0.2489  ± 0.0016 −0.17941  ± 0.00189
V3 −0.0257  ± 0.0016 0.2820  ± 0.0074 −0.748  ± 0.014

Three V spectra (Fig. 4) were fitted with double exponential functions to extract three components depending on the decay rate. Because V1 has no time dependency, V2 and V3 were fitted with double exponential functions. Each parameter is shown. Three components were extracted from the results: a time-independent component, B0, a slow decay component, B1 (rate constant k1), and a fast decay component, B2 (rate constant k2).