Skip to main content
. 2007 Apr 27;93(2):483–495. doi: 10.1529/biophysj.106.098517

TABLE 1.

Vj-dependent gating parameters for Cx40 gap junctions with low trans [KCl]

Parameter Control −Vj* +Vj* 75% trans [KCl] −Vj* +Vj* 50% trans [KCl] −Vj* +Vj* 25% trans [KCl] −Vj* +Vj*
Gmax 1.0 1.0 1.0 1.0 1.0 1.0 1.33 ± 0.005 1.16 ± 0.003
Gmin 0.17 ± 0.001 0.19 ± 0.001 0.22 ± 0.002 0.09 ± 0.002 0.32 ± 0.002 0.06 ± 0.002 0.38 ± 0.002 0.03 ± 0.002
V½ (mV) −49.7 ± 0.1 +49.2 ± 0.1 −59.0 ± 0.1 +47.0 ± 0.1 −61.3 ± 0.1 +37.9 ± 0.1 −66.8 ± 0.1 +30.0 ± 0.1
Valence (q) 3.71 ± 0.03 3.78 ± 0.03 3.41 ± 0.04 3.17 ± 0.04 3.23 ± 0.04 3.03 ± 0.04 2.74 ± 0.03 2.52 ± 0.03
Correlation coefficient (r) 0.96 0.96 0.95 0.92 0.96 0.91 0.97 0.93
N 6 6 6 6
*

Vj is defined relative to the 100% (140 mM) KCl-containing cell.

Gmax was fixed to a value of 1.0 at Vj = 0 mV for the indicated curve fit.

Gmax was not fixed to a value of 1.0 at Vj = 0 mV for the indicated Boltzmann equation curve fits.