Skip to main content
. Author manuscript; available in PMC: 2007 Nov 1.
Published in final edited form as: Acad Radiol. 2006 Nov;13(11):1344–1354. doi: 10.1016/j.acra.2006.08.003

Table 3.

Definitions and statistics used in the analysis of Morphological Blooming and kinetics as complementary methods for detecting breast cancer

Morphological Blooming Kinetics Morphological Blooming plus Kinetics
How evaluated Computer analysis Reader Interpretations
Criteria for positive finding Blooming value ≥10 Median finding of “plateau” or “washout” Positive finding using either method
Sensitivity 78% 67% 89%
False negatives 10/45 15/45 5/45
Sensitivity on set of false negatives from complementary method 10/15 (67%) 5/10 (50%)