Skip to main content
. 2007 May 4;73(13):4110–4118. doi: 10.1128/AEM.02546-06

TABLE 6.

CLAT detection of F+ DNA coliphage field isolates

F+ DNA coliphage detection method No. (%) of F+ DNA coliphage field isolatesc (n = 164)
No. (%) of false-positive results for F+ RNA coliphage field isolatesc (n = 132)
True positive False negative
CLATa 161 (97.7)b 3 (2.3) 3 (1.8)
RNase neutralization assay 164 (100) 0 0
a

CLAT for F+ DNA coliphages used both M13 antiserum (1:8 antiserum dilution) and Fd antiserum (1:16 antiserum dilution).

b

No significant difference was detected between the proportions of truly positive F+ coliphage DNAs detected by the two methods (P value = 0.82).

c

Field isolates were plaque-purified enrichments of coliphages recovered from estuarine water and shellfish.