Sensitivity of the IDI-MRSA-based screening strategy to detect MRSA-colonized patients

Swab source(s) No. of positive swabs detected/no. of true-positive swabsb % Sensitivity
Nares 54/71 76
Rectum 54/71 76
Othera 10/18 56
Nares and rectum 67/70c 96
Nares, rectum, and other 72/72 100
a

Other sources included open wounds and line exit sites.

b

The number of positive swabs detected is the number of samples from the site(s) specified detected as positive for MRSA by IDI-MRSA. True-positive specimens were defined as those determined to be positive by culture or those corresponding to specimens from other sites collected on the same day and found to be positive by culture.