Skip to main content
. Author manuscript; available in PMC: 2007 Aug 13.
Published in final edited form as: Clin Neurophysiol. 2005 Sep;116(9):2037–2043. doi: 10.1016/j.clinph.2005.06.001

Table 1.

Accuracies (%) of estimation by the IC method for different electrode configurations. Source configuration: Case A.

Electrode Number Penalty Function Noise (%) Accuracy (%)
One Two Three Four Five
5 99 91 51 22 25
10 100 78 32 10 16
32 C4 20 100 45 7 4 4
30 99 27 1 2 2
40 99 15 0 0 0

5 98 96 83 46 21
10 100 90 53 17 0
64 C4 20 100 74 15 3 0
30 100 57 0 0 0
40 100 31 0 0 0

5 97 94 93 76 56
10 97 92 88 49 23
128 C3 20 99 90 65 25 5
30 99 84 40 14 1
40 99 75 18 4 0

5 96 90 86 72 69
10 96 97 92 69 36
256 C3 20 98 95 82 39 5
30 99 94 54 20 1
40 100 91 40 0 0