Skip to main content
. 2005 Feb 24;61(Pt 3):315–318. doi: 10.1107/S1744309105005014

Table 1. Data-collection statistics for OprM crystals.

Values in parentheses are for the highest resolution shell.

Wavelength (Å) 1.0052
Crystal-to-detector distance (mm) 400
Exposure time per degree (s) 10
Space group C2
Unit-cell parameters (Å, °) a = 152.6, b = 87.9, c = 355.9, β = 98.9
Resolution (Å) 88–3.8 (4.01–3.80)
No. of measured observations 131301 (17427)
No. of unique reflections 40566 (5260)
Data completeness (%) 87.7 (77.9)
Data redundancy 3.2 (3.3)
Rmerge (%) 12.2 (31.2)
I/σ(I) 8.5 (3.3)

R merge = Inline graphic Inline graphic, where I(h) is the observed intensity and 〈I(h)〉 is the mean intensity of reflection h over all measurements of I(h).