Skip to main content
. 2007 Jun;93(6):703–707. doi: 10.1136/hrt.2006.107524

Table 3 Procedural characteristics and complications.

TMZ group (n = 136) Control group (n = 130) p Value
Stent length (mm) 12.3 (3.2) 11.8(3.2) 0.2
Stent diameter (mm) 3.13 (0.42) 3.06 (0.46) 0.2
Total inflation time (s) 30 (5) 30 (5) 1
Inflation maximal pressure (atm) 13.3 (0.2) 13.3 (0.4) 1
TIMI flow grade ⩽2, n (%) 0 (0) 3 (2) 0.22
TIMI flow grade  = 3, n (%) 136 (100) 127 (98) 0.23
ST change during inflation, n (%) 29 (21) 36 (28) 0.23
Procedural complication, n (%)
 Side‐branch occlusion 13 (10) 6 (5) 0.12
 Coronary dissection 12 (9) 13 (10) 0.74
 No reflow 0 3 (2) 0.26
 Coronary spasm 0 3 (2) 0.26
 Coronary embolisation 1 4 (3) 0.36
Increase in cTnI, n (%) 30 (22) 26 (20) 0.68

cTnI, cardiac troponin Ic; TIMI, Thrombolysis In Myocardial Infarction Trial; TMZ, trimetazidine.