Skip to main content
. 2007 May 11;93(6):2265–2276. doi: 10.1529/biophysj.106.094474

TABLE 2.

Reference Range of point stiffness (N/m) Probe type Stiffness per unit length (103 N/m2) Stiffness per unit area (106 N/m3) Shear modulus (kPa) Location along the cochlea Animal
This work 0.008–0.3 Metal probe; diameter, 25 μm 0.32–12 16.3–61 0.1–1.2 Base to apex Gerbil
von Békésy (32) 0.1–10 hair Base to apex Human
Zwislocki and Cefaratti (20) 0.116–0.125 Glass fiber, 1 μm 0.625 Midcochlea Gerbil
Abnet and Freeman (35) 0.18 Magnetic bead, radius ∼10 μm Mouse
Hemmert et al. (9,11) 0.1∼0.6 AFM cantilever <1 μm ∼10–60 ∼320–1900 Apex Mouse
Freeman et al. (30,31) 0.06–0.34 AFM cantilever <1 μm/magnetic bead Apex Mouse
Shoelson et al. (25) AFM cantilever <1 μm 1.2–8.6 Three segments along the cochlea Guinea pig
Gueta et al. (38) 0.019–0.014 AFM cantilever (tip radius, 20 nm) Base to apex Mouse
Masaki et al. (37) 0.0009 Base to apex Mouse