Skip to main content
. 2007 Jul 30;5:83. doi: 10.1186/1477-7819-5-83

Table 4.

Residual ultrasound lesion characteristics seen on interval follow-up ultrasound imaging (n = 188): For all cases (n = 34), for cases in which an attempt to completely excise the breast lesion was made (n = 19), and for cases in which only diagnostic tissue sampling of the breast lesion was undertaken (n = 15)

All cases
(n = 34)
Attempted lesion excision
(n = 19)
Only diagnostic lesion sampling
(n = 15)
P-value
Residual ultrasound lesion measurements
 Dimension 1 (cm) 0.95
(0.32–2.50)
0.79
(0.46–1.70)
1.37
(0.32–2.50)
0.003
 Dimension 2 (cm) 0.74
(0.29–2.03)
0.70
(0.42–1.50)
1.02
(0.29–2.03)
0.022
 Dimension 3 (cm) 0.53
(0.26–1.50)
0.44
(0.26–0.81)
0.86
(0.29–1.50)
< 0.001
 Volume of lesion (cubic cm) 0.18
(0.01–3.93)
0.13
(0.03–1.07)
0.65
(0.01–3.93)
0.006
Percentage of volume of residual ultrasound lesionas compared
to volume of original ultrasound lesion
33%
(3%–366%)
22%
(3%–78%)
84%
(12%–366%)
0.002